background image

 
 

 

 

-17- 

 

 

iCharger Synchronous Balance Charger/Discharger                                                      208B

 

Discharging a Lithium battery 

In  this  mode,  you  can  set  the  target  per-cell  voltage  and  hence  the  final  voltage  (final  voltage=cell 
voltage*number of cells). The lowest allowable cell voltage depends on the type of Lithium battery: 2.50V for 
Lilo, 3.00V for LiPo and 2.00V for LiFe per cell. If the battery is connected to the balance port, the 

iCharger 

can

 

monitor  the  individual  cell  voltages.  The  discharge  will  stop  immediately  if  any  cell  falls  below  the 

configured final voltage.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Note: 

If you connect the balance port at the beginning of the discharging process, then the balance port will 

monitor each cell‘s voltage, if one of these cells‘ voltage reaches the termination voltage then the process will 
terminate with ―balance port low cel vol‖. For example in LiPo mode, if one cell‘s voltage reaches 3.0V the 
process will stop. 
 
If you want to avoid this ―balance port low cell vol‖ message, then you can connect the balance port after the 
discharge  process  has  started.  In  that  case  the  process  won‘t monitor  each  cell‘s  voltage,  just  the  pack‘s 
voltage and the discharge process will terminate when the pack voltage reaches the termination voltage (= 
target_cell_voltage x number_of_cells). For example in LiPo mode, the discharge process won‘t terminate 
until the pack‘s voltage reach N*3.0V. 

Discharge Lithium battery. The left side of the first line set the type of battery 
(LiPo, Lilo or LiFe) and the value on the right side shows the final discharge 
voltage  of  each  cell.  The  value  on  the  left  side  of  second  line  sets  the 
charge current and the value on the right side of second line sets the  cell 
count and voltage of the battery pack. After setting the current and voltage, 
press 

Start/Enter

 for more than 3 seconds to start the next process.   

Per-cell final voltage: 

LiPo (3.00 

 4.20V), Lilo (2.50 

 4.10V), LiFe (2.00 

 3.60V)

 

Discharge current: 0.05 

 20A , Cell count: 1 

 8S   

 

The  number  of  cells  you  set  and  the  processor  detects.  If  the  checking 
result is the same, it would enter to the next interface; if not the same, the 
left side of the first line ‘R:xxSER‘ shows the number of cells detected by the 

iCharger

 and the right side of the first line ‘S:xxSER‘ is the number of cells 

set  by  the  user.  Usually,  the  auto-detect  number  won‘t  lower  than  the 
number set by the user. You should make sure that the configured number 
and the actual number for the battery are the same and then you can start 
charging by pressing 

Start/Enter

. If not, press 

Batt type/Stop

 to go back to 

the previous screen and adjust the setting. 

 

Discharge  process.  The 

iCharger 

allow  its  user  to  alter  the  discharging 

current during the process. Press

 Start/Enter 

to make the discharge current 

blink then press

 Inc

 

to increase or press 

Dec 

to decrease the value and 

press

 Start/Enter 

to confirm the alteration. You can stop discharging at any 

time by pressing 

Batt type/Stop

. Press 

Inc

 

to display each cell‘s voltage 

(see  the  balance  voltage  information)  and  press 

Dec 

to  display  the 

General Status information. 
 

   

 

 

LiPo DCHG  3.30V 
1.0A   11.1V(3S)

 

 

Start/Enter 

>3 seconds 
 

Batt type 

stop

 

   

 

 

R:04SER  S:03SER 
CONFIRM(ENTER)

 

 

Start/Enter 
 

Batt type 

stop

 

Battery 

Series

 

V-BP

 

Charge 

Current

 

   

 

 

Li03 1.0A 12.60V 
DSC 00993 59m:51 

battery 

voltage 

number 

of cells 

 

 

Series 

discharge 

capacity

 

discharging 

time 

discharge 

current 

work 

state 

Dec

 

Inc

 

 

Dec

 

Inc

 

 

Dec

 

Inc

 

 

Summary of Contents for 208B

Page 1: ......

Page 2: ...xternal Expanding Discharge Mode 18 Cycle Mode for a Lithium Battery 19 Lithium Battery in Monitoring Mode 19 NiCd NiMH Battery Program 20 Charging a NiCd NiHM Battery 20 Discharging a NiCd NiMH Battery 20 Cycle Mode for a NiCd NiMH Battery 20 NiCd NiMH Forming Charge 21 Pb lead acid Battery Program 22 Charging a Pb Battery 22 Discharging a Pb Battery 22 Special Modes Program 23 Electric Motor Dri...

Page 3: ...rce The iCharger series can be used with three types of Lithium batteries LiPo Lilo LiFe and has a fully integrated cell balancer Internal temperature sensor and temperature controlled automatic cooling FAN controls the internal temperature and provides intelligent protection When the internal temperature is over 60 140 o F the output power is automatically reduced by 25 If the temperature exceeds...

Page 4: ...In this mode the charger acts as a convenient power supply for a hot wire foam cutter Battery interior resistance measurement The iCharger can not only measure the internal resistance of the battery pack and also can measure the per cell internal resistance only available for lithium battery Perfect protection The iCharger has protection for reversed polarity input or output low input voltage batt...

Page 5: ...ir of output alligator clip leads One pair of input alligator clips 30A and input leads with 4mm bullet connectors One temperature sensor lead 0 99 210 o F Four rubber feet One exclusive Mini USB data line 1 2 meter Optional items See details in Optional parts P32 External controls and connections 208B 1 DC input 2 LCD screen 3 Function button 4 Cooling Fan 5 Temperature sensor port 6 Balance sock...

Page 6: ...lor change or distortion Do not try to charge non rechargeable dry cells Do not exceed the battery manufacturer s suggested maximum charge rates Beware that the external case temperature of the charger will increase during charging discharging at high power Carefully follow the battery pack manufacturer s recommendations and safety advice Recommended connecting way 1 Connect iCharger s input power...

Page 7: ...ngs PROGRAM SELECT Load settings SAVE SETTINGS XX memoryX LOAD SETTINGS XX memoryX Batt type Dec Inc PROGRAM SELECT Special modes MOTOR DRV XXmin X XA XX XV Completion Ring Beep XXX Back light XX Cooling fan XXXX Capacity Cut Off XXX XXXXXmAh NiMH NiCd Pb Trickle XXXmA NiMH Sensitivity DeltaV XXmV Cell Lithium battery Check Time XXmin Bal Speed XXXXXX Bal Trickle XXX Temp Cut Off XXX XX NiMH NiCd ...

Page 8: ... Start Enter together for more than 3 seconds to obtain this display 8 Adjust Current Temp Cut Off Safety timer Capacity Cut Off in course of charging and discharging Method of Application When in charging and discharging interface press Start Enter for 3 seconds and current begins blinking Press Inc or Dec to adjust current and press Start Enter to save changes If users press Stop Batt type or wi...

Page 9: ...rmal is between the Fast and the Slow If Bal Trickle is ON the iCharger won t stop charging until the current falls to around 20mA Bal Speed Fast Normal Slow Normal default Bal Trickle OFF ON OFF default For balance charging Li battery There are three balance modes options CV phase storage voltage and always If the balance mode is set to CV phase when any cell s voltage reaches the set voltage for...

Page 10: ...ltage protection lower limit The charging discharging process will stop immediately if the input voltage falls below the set value Range 4 50 30 00V 4 50V default Current Range 1 0A 25 0A 25 0A default Note Current limit is not very accurate which may be 20 difference max Charge Discharge power limit The maximum charge discharge power of iCharger can be adjusted in order to limit internal temperat...

Page 11: ...any key If the buzzer is ON the iCharger will generate an alert tone for certain events Key Beep OFF ON ON default Buzzer OFF ON ON default Process completion tone Controls the tones generated at end of charging or discharging and the cyclic charging discharging indication Options Beep 5 times Beep 3 minutes Beep always continuous until user presses STOP Beep OFF Beep always default Back light and...

Page 12: ...4 20V Step 0 01V 4 10V default Termination voltage for LiPo Adjust LiPo s charge termination voltage Press Start Enter for more than 3 seconds to blink the Voltage value then press Dec and Inc to adjust the termination voltage Range 4 00V 4 30V Step 0 01V 4 20V default Termination voltage for Pb Adjust Pb s charge termination voltage Press Start Enter for more than 3 seconds to blink the Voltage v...

Page 13: ...will compensate voltage Any time the battery s balance lead is connected the charger will monitor and display the cell voltages The balancer is only active during a BALANCE charge not during the CHARGE or FAST programs The balance speed setting Slow Normal Fast controls the end of charging current threshold The CHARGE and FAST modes are identical except for the charge termination threshold which i...

Page 14: ...LiPo Lilo or LiFe The value on the left side of second line sets the charge current and on the right side of second line it shows AUTO The system will check cell count automatically by cell balance port s voltage Charge current 0 05 20A Voltage 1 8 series Lithium BALANCE charging mode The screen shows the status during the charging process You can stop charging at any time by pressing Batt type St...

Page 15: ...You can stop charging at any time by pressing Batt type Stop Press Inc to display each cell s voltage see the balance voltage information and press Dec to display the General Status information battery voltage number of cells Series charged capacity charging time charge current work State The fast charging mode of Lithium battery The left side of the first line set the type of battery LiPo Lilo or...

Page 16: ...nd the right side of the first line S xxSER is the number of cells set by the user You should make sure that the configured number and the actual number for the battery are the same and then you can start charging by pressing Start Enter If not press Batt type Stop to go back to the previous screen and adjust the setting Lithium STORAGE charging mode The screen shows the status during the charging...

Page 17: ...ets the charge current and the value on the right side of second line sets the cell count and voltage of the battery pack After setting the current and voltage press Start Enter for more than 3 seconds to start the next process Per cell final voltage LiPo 3 00 4 20V Lilo 2 50 4 10V LiFe 2 00 3 60V Discharge current 0 05 20A Cell count 1 8S The number of cells you set and the processor detects If t...

Page 18: ...ating capacity of the external capacity resistance For example discharge a pack of 20V lithium battery at 7A R 20V 7A 2 85Ω P 20V 7A 140W Discharge Lithium battery The left side of the first line set the type of battery LiPo Lilo or LiFe and the value on the right side shows the final discharge voltage of each cell The value on the left side of second line sets the charge current and on the right ...

Page 19: ...een and adjust the setting Charging discharging cycle mode of Lithium battery In this process you can stop the cycle at any time by pressing the Batt type Stop button In the process of C D or D C the blink C indicates charging while D indicates discharging Press Inc button to display each cell s voltage and its past cycling current see the balance voltage information cycling information and press ...

Page 20: ...e left side of the first line shows the type of battery NiCd NiMH and the right shows the cycle number The second line shows the cycle direction you selected CHG xxx DCHG or DCHG CHG xxx You can set the charge mode as Charge Auto or Charge Manual The discharge parameters are those set in NiCd NiMH discharge screen Press Start Enter for more than 3 seconds to start the cycling Cycle number 1 999 on...

Page 21: ...y NiCd NiMH The value on the left side of second line sets the cell capacity and the value on the right side of second line sets the cell count and nominal voltage of the battery pack Press Start Enter for more than 3 seconds to start charging Forming capacity 0 1 9 9Ah Cell count 1 25S Forming status You can stop the process at any time by pressing Batt type Stop and display the General Status in...

Page 22: ... charging Charge current 0 05 20A Battery cells 1 18P 2 36V Status display You can stop the charging process at any time by pressing Batt type Stop Press Dec to display the General Status information Discharging Pb battery The left side of the first line shows the type of battery Pb The second line shows the charge current on the left and number of cells on the right After setting the current and ...

Page 23: ...ght corner alternately displays the output power or total run time You can stop the test at any time by pressing Batt type Stop Start Enter 3 seconds Batt type Stop MOTO 1 9A 2 05V DRV 00310 3 8W drive voltage drive capacity power or time drive current work state motor test MOTOR DRV 10min 8 0A 2 0V Dec Inc Dec Inc The value on the right side of the first line sets the run duration in minutes The ...

Page 24: ...nter 3 seconds Batt type Stop 1 21 24 19mΩ 4 18 26 16mΩ Measure Internal Resistance Measure internal resistance You can press Start Enter for more than 3 seconds to start the process and stop at any time by pressing Batt type Stop The two lines show the first to the sixth cell s internal resistance which is only available for the lithium battery Press Inc or Dec to display more information of the ...

Page 25: ... 00 refers to the target memory number the user wants to choose In the second line the memory0_ refers to the character the user wants to input Press Inc Dec button to walk letters and then press Start Enter button to confirm the chosen letter and moves to the nest letter position when you finish the character press Start Enter button twice to confirm the character You can delete a wrong chosen le...

Page 26: ...e than 3 seconds PROGRAM SELECT Log files 2016Kb Start Enter 3 seconds Dec Inc Start Enter Batt type stop Free Capacity Free Time File Create LogFile3_ File Empty CONFIRM ENTER File Transfer 00050 01000 File Delete CONFIRM ENTER User defined the files name Name setting method Press Inc or Dec to choose the letter press Start Enter to confirm your selection and move to the next one press Batt type ...

Page 27: ...Press Inc or Dec to check the parameter value related to the error For example in the case of a temperature error you can check the temperature that triggered the error Press Start Enter to return to the error message screen Expression refers to the discharged capacity to packs Termination at 01245mAh 01h 32 Termination time Termination power Inc CHG 1 00213mAh DCHG 1 00199mAh CHG 2 00203mAh DCHG ...

Page 28: ...thout using the balance port the cell count detected by the charger is less than that set by the user Please check the cell count of the battery pack Without using the balance port the cell count detected by the charger is higher than that set by the user Please check the cell count of the battery pack The internal temperature is over 65 149 o F Cool down the unit The external temperature sensor d...

Page 29: ...teps Install the iCharger USB driver Run the program X Upgrader Upgrader exe you can download the Upgrader exe software from the following website http www jun si com UploadFiles Upgrader rar Connect the iCharger to the PC using the supplied USB cable choose Device in Device List then select the upgrade file you can download the latest file The progress bar will appear after you click Update Note ...

Page 30: ... driver for the iCharger Communication steps To install LogView run the program X logview LogViewInstaller exe where X is the drive letter designator for you CD ROM drive Connect the iCharger to the PC using the supplied USB cable Start LogView then follow the illustrated instructions below 1 Please choose language first since the default language is German 2 Click Device Choose device and port ...

Page 31: ... 3 Choose iCharger 208B from the list and then choose the correct communication Port 4 Start iCharger s charge or discharge mode then click Start recording to record data Refer to the LogView online help for more information about its features and operation ...

Page 32: ... with magnet 4mm banana gold plug to JST output wire 4mm banana gold plug to T plug output wire Power supply Specifications Input Voltage Range 100 240VAC Input Frequency 50 60Hz Output Voltage 14 9 15 5VDC Output Current 0 23A Operating Temperature 10 40 Storage Temperature 40 80 Dimension L X W X H 185 X 88 X 47mm Weight 700g CB1010 XH 70 X 44mm CB1010 EH CB1010 AQP CB1010 TP 70 X 44mm 68 X 51mm...

Page 33: ... power supply automotive battery charger etc water moisture and humidity are specifically NOT covered by warranty It is better checking your charger carefully before considering returning it as problems in setup cabling or power supply are much more common than defects in the charger If there is damage stemming from these causes within the stated warranty period the company will at its option repa...

Reviews: