iCharger Synchronous Balance Charger/Discharger 208B
Measuring internal resistance of the battery
In general, the internal resistance of a battery is not a fixed value. It varies over time as the battery loses
energy and also varies depending on the load, or how much current is drawn from the battery. One of the
urgent requirements of a battery is low internal resistance. Measured in milliohms, the internal resistance is
the gatekeeper that, to a large extent, determines the runtime. The lower the resistance, the less restriction
the battery encounters in delivering the needed power spikes.
The
iCharger
can not only measure the internal resistance of the battery pack, and also can measure the
per-cell internal resistance
(
only available for lithium battery
)
.
Note
: You can check the internal resistance by
Present testing information
; see detail information in Page
8.
Start/Enter
>3 seconds
Batt type
Stop
1: 21 24 19m
Ω
4: 18 26 16m
Ω
Measure Internal
Resistance
Measure internal resistance. You can press
Start/Enter
for more than 3
seconds to start the process and stop at any time by pressing
Batt
type/Stop.
The two lines show the first to the sixth cell‘s internal resistance, which is
only available for the lithium battery. Press
Inc
or
Dec
to display more
information of the seventh to the tenth cell‘s internal resistance. Press
Start/Enter
to measure it again, and press
Batt type/Stop
to return to the
main menu.
The two lines show the seventh to the tenth cell‘s internal resistance,
which is only available for the lithium battery. Press
Inc
or
Dec
to
display the General Status information. Press
Start/Enter
to measure it
again, and press
Batt type/Stop
to return to the main menu.
Status display. This screen displays the battery pack internal resistance.
Press
Inc
or
Dec
to display the General Status information. Press
Start/Enter
to measure it again, and press
Batt type/Stop
to return to the
main menu.
Battery Pack IR
173m
Ω
Inc
Dec
Inc
Dec
7: 20 29