21
2 : Operation time setting after sales
Set the operation delay time of the air pump sales.
After the motor operation is stopped, the air pump
is additionally operated according to the time set
for this category.
3 : Operation time set after button input
Set the time that the air pump operates every time
the button is pushed.
4-18 : Select the use of pasteurization.
4-19 : Button lock function setting
Byactivating this category, the buttons (refers to the work
mode buttons on the right such as auto, wash, heating,
stand-by, refresh, refrigeration, and so forth) can be
locked. Press both the "-" button and the "+" button for
5 seconds, in order to lock the buttons and do the same
in order to unlock the buttons.
4-20 : Voltage corresponding current compensation setting
This is the function for compensating the current value
when the voltage is easily changed during the making
of soft freezer.
This product consumes a lot of power. Therefore, install
and make sure it has a supply of enough stable power.
4-22 : Compressor delay time setting
This sets the compressor's operation delay time after
making soft freezer. If this category is given much time,
soft freezer can be frozen too much and problems
can occur to the product.
4-23 : Selection of the compressor forced operation
This is the function for forcibly operating the compressor
during rest time when the compressor is not operating.
The following categories appear when the compressor
operation time is set in this category.
4-24 : Temperature detection time setting after stop
This chooses the time to determine the temperature
during the rest time. In case "4n" is chosen, it means,
"detecting temperature 4 minutes after rest."
It sets the temperature for operating the compressor.
4-25 : Operation temperature selection
This detects the temperature at the time set in Category 4-24
and sets the temperature at which the compressor can be operated.
The compressor is operated for duration stipulated in Item 4-23
when the temperature reaches the temperature that was set for thiscategory.
4-21 : Dasher motor delay time setting
Sets the motor's operation delay time after making soft freezer.
Detailed description of each mode