![icetro ISI-300TA User Manual Download Page 19](http://html1.mh-extra.com/html/icetro/isi-300ta/isi-300ta_user-manual_610577019.webp)
19
Detailed description of each mode
4-4 : Standby off temperature setting
This sets the cylinder's raw material storage temperature
in the standby mode. When the temperature of this category
is too low, the raw material inside the cylinder freezer
and soft freezer can become like porridge.
4-5 : Standby management temperature setting
This sets the management temperature to refrigerate the raw
material in the hopper. The temperature set in this category is
managed the value added from the value in Categories 3-4.
For example, if 3-4 is 2℃ and 4-3 is 2℃, the management
temperature of the hopper is maintained at 6-8℃.
4-6 : Standby reset time setting
This sets the motor's operation cycle to the standby mode.
When one is satisfied with the temperature value of 4-4 plus
4-5 and the time of this category, the motor and compressor
are operated.
4-7 : 1℃ rise level calculation (The left digit)
When the soft freezer is made, 100% is displayed on the green
FND window and the percentage value is deducted from the
compressor rest time.At this time, when 1℃ is added to the
temperature at which the soft freezer is made, the value set for
this category is deducted from the percentage and is then displayed.
4-7 : 30 seconds pass level calculation (The right number)
When the soft freezer is made, 100% is displayed on the green
FND window and the percentage value is deducted from the
compressor rest time. At this time, the value set for this category is
deduced from the percentage every 30 seconds after the making
of the soft freezer and displayed.
4-8 : Upper limit current setting
This category sets the maximum value when adjusting
the hardness of the soft freezer in Category 3-1.
This category's value needs to be set within the range, in which
excessive current does not flow on the motor.
4-9 : Maximum pasteurization time setting
It is set to stop pasteurization when gas leaks or when
problems occur in the pasteurization device. If pasteurization
continues until the time set for this category
4-10 : Select between Celsius and Fahrenheit
Select between Celsius (℃) and Fahrenheit(℉)