2. Installation
Specifications for connecting water supply
[ Connecting water piping / hose ]
Appropriate water temperature
Water pressure
Appropriate piping
/hose size
Cooling water supply
50 ~ 90
℉
20 ~ 80 psi
3/8" FPT(NPT)
Cooling water outlet
-
-
3/4" FPT(NPT)
Ice making water supply
50 ~ 90
℉
20 ~ 80 psi
3/8" FPT(NPT)
Ice making water drain
-
-
3/4" FPT(NPT)
Too high temperature of the ice-making water will decrease the amount of ice produced; too
low pressure will prevent ice from being made at all. Install an auxiliary pressure pump in this
case.
IM/WM-0460-AC/AH/WC/AH, IM/WM-0460-AC/AH(115V),
IM/WM-0680-AC/AH
Water Cooled only
Ice making water
supply inlet (3/8" FPT)
Cooling water
supply outlet
Cooling water
supply inlet
Container water outlet
Ice making water drain
(3/4" FPT)
Leftover water outlet from cooling
part
IM/WM-0460-AC/AH/WC/AH-22
Water Cooled only
Ice making water supply
inlet (3/8" FPT)
Cooling water supply inlet
Ice making water drain (3/4"
FPT)
Container water outlet
Cooling water supply (3/4"
FPT) outlet
13
Summary of Contents for IM/WM-0460-AC
Page 34: ...MEMO 34...
Page 35: ...MEMO 35...
Page 36: ...Online Internet Service http www icetrousa com 3240288 05...