43
3. Water amount control supplying to the water through
Ice thickness probe clearance adjustment
ⓐ Open the front door by loosing top and bottom bolts
ⓑ Adjust clearance by using adjustment screw on ice thickness probe like picture in right
ⓒ lf water supply is not enough since adjust ice thickness thicker than factory setting,
Please set FND PCB to extend water supply time as under.
ⓓ lf ice thickness is set thicker, extend water supply time and set thinner decease
water supply time.
▶ Press set of FND. Version is showing, then press increase or decrease to move me
until the below image appears
▶ Press set and value appears. This value is extended water supplying time. lf this setting
is done, water is supplying to water through additionally for a certain period of time after
high level sensed high level.
▶ Increase time or decrease time by pressing "increase" or "decrease"button.
(setting time is second)
Factory
setting
IM-1100-RC
IM-1100-RH
5.0 mm
4.5 ~ 5,5 mm
IM-1700-RC
IM-1700-RH
5.5 mm
5,5 mm
IM-2000-RC
IM-2000-RH
5.5 mm
5,5 mm