23
※ The ice maker should be cleaned and disinfected at least twice a year.
More frequent cleaning and disinfection may be required.
1. Washing solution
Use a scale remover that is not harmful to human body by diluting with water, and use more
amount if necessary.
It is important to use the diluted cleaning solution immediately for safety and maximum effect.
2. Washing procedure
1) Shut off the water supply by locking the valve of the water line of the ice maker.
2) Switch the ICE MAKING-OFF-WASH switch to the "WASH" position.
3) The water in the water tank is drained through the evaporator cylinder and washing is done
by this (max. 5 minutes).
4) Turn the ICE MAKING-OFF-WASH switch to "OFF" position.
5) Remove all ice from the ice maker and reservoir.
6) Pour the wash solution into the wash solution inlet until the evaporator assembly
and the water tank are full.
(Until the wash solution overflows to the drain box)
7) Leave the ice maker for 10 minutes before starting operation. If the water supply hose is
clogged in step 7, remove it before operation.
8) As described below, please disassemble and clean the water level sensor (high and low)
if it is in bad water condition.
If not, proceed to step 9.
ⓐ Remove the water level sensor from the water tank cover.
ⓑ Clean the level sensor with washing solution.
ⓒ Wash the water level sensor thoroughly with clean water.
ⓓ Fix the level sensor to the correct position.
9) Switch the ICE MAKING-OFF-WASH switch to the " ICE MAKING " position to start the ice maker.
Keep it running until ice making stops.
(※ Water supply valve should be locked so that water
is not supplied.)
10) Switch the front ICE MAKING-OFF-WASH switch to the "WASH" position, and drain the remaining
water in the water tank and evaporator cylinders for 5 minutes.
11) Switch the ICE MAKING-OFF-WASH switch to the "OFF" position.
12) Open the water supply valve of the ice maker, and switch the ICE MAKING-OFF-WASH switch
to the " ICE MAKING " position so that water can be supplied to the water tank.
13) When the geared motor is activated, switch the ICE MAKING-OFF-WASH switch to the "WASH"
position and drain the water (drain is possible for 5 minutes).
14) Turn OFF the power switch and disconnect the power cord from the outlet.
How to clean and disinfect
◆
Make sure to comply with the following.
●
Do not use ammonia-based detergent to prevent damage to the personnel or the ice maker itself.
●
Cleaning and sterilizing must be conducted in accordance with the instructions on the user manual.
●
Always wear protective gloves and goggle to prevent skin or eye from coming into contact
with the sterilizing solution.
●
Do not use the ice made with the cleaning or sterilizing solution after cleaning and sterilizing.
Make sure that no sterilizing solution is left on any part of the ice maker and the ice storage bin.
Warning