18
We Think of Customer Satisfactio
n
Function Button Description (FND Display Window)
Set the maximum opening time of the ice dispense valve.
(Adjustable in 1 second increments, default is 20 seconds.)
→ Even if you keep pressing the ejection lever, ejection is not
possible beyond the time set in this item.
It is a function to dispense ice at once.
(Ice is dispensed regardless of the set value of F1.)
→ This function is activated by turning off the mode switch
and pressing the water button and ice button at the same time for 3 seconds or longer.
It is a function to dispense ice at a set time.
(Adjustable in 1 second increments)
→ This function is only used in the ice mode.
If you touch the ejection lever, the ice is ejected at the set time and automatically closes.
This function drains the water stored in the reservoir.
(The first and second digits of FND adjust the drainage time (in seconds))
(The fourth digit of FND controls the number of repetitions)
→ This function is performed at the first ice making after power is turned on.
It is a function to periodically drain water when making ice.
(The second digit of FND adjusts the drainage time (in seconds))
(The 3rd and 4th digits of FND adjust the multiplication interval (in units of 30 seconds))
→ This function is activated when ice making.
In the simultaneous dispensing mode of ice and water, each dispensing time is adjusted.
(The first and second digits of the FND are the ice dispensing time)
(The 3rd and 4th digits of FND are water drain time)
→ Even if the dispensing time is increased in this item, it is limited in the “F1” item.
It is a function to operate the UV lamp periodically.
(The first and second digits of FND are the lamp lighting time (in minutes))
(The 3rd and 4th digits of FND are the lamp off time (in hours))
→ The UV lamp always operates periodically regardless of the discharge.
AUGER It is a function to control the usage time alarm and warning.
(If “A” is displayed, it is a function to set the usage time alarm)
(If "E" is displayed, it is a function to set the usage time warning)
→ This item can be adjusted from 0.1 to 9.9, and 0.1 is 1000 hours.
Check the AUGER usage time.
(FND displays "Year, Month, Day, Time" sequentially)
Check the AUGER usage time.
(FND displays "Year, Month, Day, Time" sequentially)
Displays EVA OUT temperature.
Check the number of times the wash is complete.
(After washing the product, set the mode switch to "OFF" and press the "In
Decrease" button simultaneously while the FND version is displayed, and the number of
washing increases by one.)
→ Counter reset is initialized by pressing the push button inside the PCB within 1 second.
It is used only in "Ice+Water" mode and selects the method of dispensing ice and water.
(If “A” is selected, water is dispensed after ice is dispensed, and if “B” is selected,
water is dispensed at the same time)
Check the number of resets.
(FND 1 and 2 digits indicate the reset number of the AUGER operation time, FND 3 and
4 digits indicate the washing reset number)
Set the ice dispensing time of the small cup.
(The button is the left button on the PCB)
→ Displayed when CVS mode is activated (DIP S/W No. 1 ON).
Set the ice dispensing time of the large cup.
(The button is the right button on the PCB)
→ Displayed when CVS mode is activated (DIP S/W No. 1 ON).
Set automatic return to ice dispensing mode
(“small cup dispensing”when CVS is activated).
(After waiting time of 3 or 4 digits of FND, it is automatically changed to ice dispensing mode)
→ When set to A.OFF, it does not automatically return.
This is the manual input function of AUGER usage time.
(Before updating the main board and program, change from "OFF" to "ON" in this item and
press the Set button to save the AUGER time in FND)
→ When MAIN board and program are updated, it is automatically transferred from FND
to MAIN board.
It is a function to periodically agitate the AGITATOR in the ice storage container.
(1st and 2nd digits of FND are the time to stop the stirrer, "0.1" is 6 minutes, the 1st and
2nd digits of FND are the time the stirrer is running, and "1" is 1 minute)
Displays the COND OUT temperature.
(If DIP S/W No. 3 is OFF, this item sets the high pressure detection and release temperature)
→ If you press the setting button in this item, "H" is displayed to set the high pressure
sensing temperature, and if you press the setting button again, "L" is displayed to set the
high pressure release temperature.