Mechanical Seal
1. Remove the three (M8) fixing bolts and lift the auger/extruder head out.
2.
If the wear tolerance of the ice outlet head bearing exceeds 0.5mm (0.02”) or if there are scratches, replace it.
3. Lift the extruder and auger up.
4. If the bearing contact is worn or the blade is scratched, replace the auger.
3 x M8 head bolts
with o-rings
Auger
Extruder
Housing
Evaporator
Coupling
Disassembly ID-0160
Removal and Replacement of Ice Hopper, Extruder, Auger, & Evaporator
▪
Extruder & Auger
* The mechanical seal is attached to the bottom of the auger.
Replace the seal when it leaks at the bottom of the evaporator.
Ceramic seal is on top of the lower housing assembly.