Flexible Numeric Display
(FND) on ID-0160
Error codes are also listed in the owner’s manual.
1) Forced Drain Function:
(Must be used to prevent water from freezing in
winter storage.)
Please also use this function to drain water before cleaning
any internal parts.
● Turn on the main power switch. Press the “DOWN” + “MODE”
buttons simultaneously for 3 seconds on the FND panel. Water will
then purge from the water sump for 30 seconds.
2) Automatic Drain Function:
● Turn on the main power switch. Press the “MODE” button until F. 5 is
displayed on the FND.
●
The 1st & 2nd digits displayed is the drain time (2 seconds) and is
adjustable in 1 second increments, up to 99 seconds.
●
The 3rd & 4th digits displayed is the drain interval (1 hour) and is
adjustable in 30 minute increments from 0.5 to 9.5 hours
3) Initial Water Draining Function:
● Turn on the main power switch. Press the “MODE” button until F. 4 is
displayed on the FND.
●
The 1st & 2nd digits displayed is the drain time (30 seconds) and is
adjustable in 1 second increments, up to 99 seconds.
●
The 3rd & 4th digits displayed is the number of repetitions (3 times)
and is adjustable from 1 to 9 times.