Disassembly ID-0160
Removal and Replacement of Ice Hopper, Extruder, Auger, & Evaporator
▪
Evaporator
2. Remove the sensing bulb from the suction line.
3. Braze out the copper pipe and expansion valve connections from the evaporator.
4. Disconnect the water hoses connected to the evaporator.
5. Remove the four bolts (M8) holding the evaporator cylinder to the housing and remove the
evaporator by lifting it up, revealing the housing in full.
1. Recover the refrigerant and store it in an approved container.
Whenever the refrigeration system is open, replace the drier and do not open the new drier until all repairs and part
replacements are complete.
4 bolts M8
(With mechanical seal stator inside)
Housing