28
DISPOSAL
To dispose of the appliance, take it to a demolition centre or an authorised collection centre.
Before scrapping the appliance, it is necessary to remove and separate out the following materials,
then send them to the appropriate collection centres in accordance with applicable environmental
hygiene regulations:
• Electric and electronic parts*
• Plastic parts
• Metallic parts
(*) In particular, contact your distributor when scrapping electric and electronic parts.
PROBLEM
POSSIBLE CAUSE
SOLUTION
THE VACUUM
CAPACITY IS
INSUFFICIENT
The vacuum hose is blocked.
Check that there is nothing obstructing the vacuum hose, if there
is, remove it.
The vacuum chamber of the
accessory in contact with the floor is
blocked.
Check that there is nothing obstructing the vacuum chamber of the
accessory being used, if there is, remove it.
The vacuum hose is not properly
connected to the vacuum nozzle.
Connect the vacuum hose to the nozzle on the collection tank.
The vacuum hose is not properly
connected to the accessory in contact
with the floor.
Connect the vacuum hose to the accessory that is being used to
do the vacuuming.
The vacuum head is not positioned
correctly.
Place the vacuum head on top of the collection tank and secure it
using the side hooks.
The fabric filter is clogged or has torn.
Remove the vacuum head from the collection tank and carry out the
maintenance of the fabric filter, read the section “
AND CLEANING THE FABRIC FILTER
”.
The sponge filter is clogged or has
torn.
Remove the vacuum head from the collection tank and carry
out the maintenance of the cartridge filter, read the section
CONTROLLING AND CLEANING THE SPONGE FILTER
The cartridge filter (optional) is
clogged.
Remove the vacuum head from the collection tank and carry
out the maintenance of the cartridge filter, read the section
CONTROLLING AND CLEANING THE CARTRIDGE FILTER
The nylon filter (optional) is clogged
or has torn.
Remove the vacuum head from the collection tank and carry out the
maintenance of the cartridge filter, read the section “
AND CLEANING THE NYLON FILTER (OPTIONAL)
”.