MAINTENANCE OVERVIEW
Y
our ICE AIR WSHP unit is designed to provide you with many years
of efficient, trouble-free comfort conditioning service. To ensure
equipment longevity and efficiency, please make sure that the
following simple maintenance procedures are followed.
This manual assumes that your WSHP unit has been installed by a
qualified installation professional, and is operating properly prior to
maintenance service.
•
Have your unit periodically inspected by a properly trained
service professional or building maintenance staff person. The
unit should be checked for the safe and proper functioning of
all of its systems at least once a year. The following recom-
mended maintenance procedures should be carried out only by
trained personnel with strict adherence to the safety guidelines
outlined at the beginning of this manual. These procedures
MUST be followed to ensure your safety and the safety of the
person maintaining the equipment.
FILTER
ICE AIR WSHPs are equipped with a washable/reusable Filter.
It is recommended that you clean the indoor air filter after
every 350 to 400 hours of unit operation - more frequently
if the unit is running in an environment of high dust, pet
dander or other pollutants in the indoor atmosphere.
•
Filter inspection: The filter is located at the bottom of your unit.
To remove unit slide it out towards you.
•
To reinstall place filter under the unit and slide back in to the
filter rack
Filter Cleaning:
To clean your filter use luke warm water with a biodegradable
cleaner rinse and allow to dry completely before installing back
to unit. (As an alternate cleaning method,
the filter may be cleaned on both sides
using a vacuum cleaner with a soft brush
type attachment.)
DO NOT OPERATE UNIT WITHOUT
FILTERS.
This practice will damage and/
or seriously impair the performance of
your unit and could void your Warranty.
CHASSIS CLEANING
Evaporator Coil and Drain Pan/Drain Hoses:
To access the components within the chassis of the unit,
disconnect unit power and then remove the unit Access Door
by unscrewing the retaining screws that hold the door in place
(use a Phillips head driver). You will then have access to the
unit chassis and components:
CAUTION:
to prevent injury or death due to electrical shock or contact with moving part,
turn off the disconnect switch before servicing this unit.
IMPORTANT NOTE:
It is not the intent of this maintenance manual to correct any installation deficiencies. If you have any
doubt about the proper initial installation (or reinstallation after servicing) of your WSHP unit(s)- noisy or inefficient unit
operation,frayed or damaged electrical connections, improper unit appearance, etc. Please contact a trained servicer or building
maintenance staff immediately.
DO NOT OPERATE ANY EQUIPMENT THAT DOES NOT APPEAR TO BE FUNCTIONING PROPERLY!
IMPORTANT NOTE:
The power MUST be disconnected before carrying
out any of the following cleaning!