OPERATING & MAINTENANCE MANUAL –

 

VERTICAL STACK WATER SOURCE HEAT PUMP (VWSHP)

3

OPERATING & MAINTENANCE MANUAL –

 

VERTICAL STACK WATER SOURCE HEAT PUMP (VWSHP)

CONSUMER SAFETY AND OPERATING NOTES:

FOR SAFE AND OPTIMAL ENJOYMENT OF YOUR ICE AIR WSHP UNIT, PLEASE READ THE FOLLOWING  CONSUMER SAFETY 
AND OPERATING NOTES CAREFULLY BEFORE OPERATING YOUR EQUIPMENT!

• 

This unit MUST be serviced only by professionally trained, qualified technicians. Do NOT attempt to maintain or service this 
unit on your own – severe injury and death can occur from electric shock, moving parts, and other hazards. 

• 

Your 

ICE AIR

 units must each be wired on an individual, dedicated electrical circuit with the correct voltage and proper 

amperage (capacity) to match the unit nameplate requirements. 

• 

Each unit’s electric circuit must have a proper overcurrent protection device, employing an approved circuit breaker or fuse  
of the proper rating under NEMA and local building codes. 

• 

Every unit contains refrigerant within a sealed and pressurized refrigerant system. This system must not be opened or  
tampered with and any refrigeration system repairs MUST be carried out by trained technicians. Refrigerant must be   
properly handled and recycled per EPA regulations and guidelines. 

• 

Your 

ICE AIR

 unit must be properly installed and commissioned to operate correctly. Improper unit installation, adjustment 

or commissioning, and / or improper piping installation and connection can lead to equipment malfunction and hazardous 
operating conditions, and may void your Warranty. If you have any doubt about the proper installation of your WSHP unit, 
please contact your property manager at once to have a qualified technician inspect the equipment. Do NOT operate the 
equipment when in doubt – have it inspected first! 

• 

Your 

ICE AIR

 equipment is covered by a manufacturer’s Warranty (see Warranty Information Sheet for full terms and     

conditions). Your unit(s) must be properly installed and kept free of obstructions. Additionally, proper cleaning of the unit 
filter, evaporator coil and all air flow areas must be maintained. Failure to do so will decrease unit function and efficiency, 
and may void your Warranty.

Summary of Contents for Vertical Stack Water Source Heat Pump

Page 1: ...Vertical Stack Water Source Heat Pump VWSHP OPERATING MAINTENANCE MANUAL World Class Comfort ...

Page 2: ...other important documents and product manuals The information contained within this Manual unless noted herein applies to all ICE AIR WSHP models If your unit has optional features they will be explained in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers SAFETY WARNI...

Page 3: ...rant system This system must not be opened or tampered with and any refrigeration system repairs MUST be carried out by trained technicians Refrigerant must be properly handled and recycled per EPA regulations and guidelines Your ICE AIR unit must be properly installed and commissioned to operate correctly Improper unit installation adjustment or commissioning and or improper piping installation a...

Page 4: ...tly and have dual element class RK5 fuses or HACR circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless other wise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not ...

Page 5: ...AUTO settings The thermostat has an LCD display with temperature set point s mode and status indication The temperature indication is selectable for ºF or ºC The thermostat provides permanent memory of set point s without batteries The thermostat provides a convenient override feature to temporarily change set point s OPERATING INSTRUCTIONS OPERATION IMPORTANT NOTE Do not attempt to restart the un...

Page 6: ...ur unit To remove unit slide it out towards you To reinstall place filter under the unit and slide back in to the filter rack Filter Cleaning To clean your filter use luke warm water with a biodegradable cleaner rinse and allow to dry completely before installing back to unit As an alternate cleaning method the filter may be cleaned on both sides using a vacuum cleaner with a soft brush type attac...

Page 7: ...carried out within an apartment If the coil requires additional cleaning the unit must be removed from the wall cabinet and cleaned using compressed air and or washed These operations MUST be carried out in a facility properly equipped to handle this type of work in a safe and professional manner Do not carry out this cleaning in a finished apartment or office area Drain Pan Drain Hose Cleaning Th...

Page 8: ...proper thermostat settings Check for fault codes on the control board consult the troubleshooting guide 2 If checks above fail to reveal operating problem If the unit still do not operate after reset contact trained service technician to conduct full unit diagnostics and repair to equipment Record any unit that does not operate noting the unit serial number on your report BOARD TROUBLESHOOTING TAB...