COOLING MODE

• 

To activate cooling, press the mode button until COOL displays

• 

Press up/down arrow keys to your desired temperature

• 

Compressor will cycle when temperature reaches the set point. 
After compressor stops, allow at least 3 minutes before restart-
ing (this applies only if you have manually turned the unit off or 
reset the thermostat - during normal running conditions, the unit 
will automatically allow for the required restart delay)

The temperature reading that is on constant display is the ambient 
room temperature.

HEATING MODE

• 

To activate heating, press the Mode button until HEAT displays

• 

Press up/down arrow keys to your desired temperature

• 

The unit will cycle until the set temperature is achieved and then 
will continuously cycle to maintain the set temperature.

The temperature reading that is on constant display is the ambient 
room temperature.

LOCKOUT SAFETY

All Ice Air WSHP units have its own lockout circuit to shut down the 
compressor during an abnormal condition. During unit operation the 
compressor will be automatically turned off due to one of these safety 
conditions.

• 

High pressure

• 

Low temperature

• 

Condensate overflow

   c)  Single Stage Manual Changeover 
    

Programmable 5/2 Day

  

 

This thermostat is 5 day/2 day programmable (with  

 

up to 4 set-points per day), single stage (1H/1C),  

 

manual changeover with HEAT-OFF-COOL system  

 

settings and fan ON-AUTO settings. The thermostat  

 

has an LCD display with temperature, set-point(s),  

 

mode, and status indication. The temperature 

  

 

indication is selectable for ºF or ºC. The thermostat  

 

provides permanent memory of set-point(s) without 

  

 

batteries. The thermostat provides a convenient 

  

 

override feature to temporarily change set-point(s).

OPERATING INSTRUCTIONS 

OPERATION

    IMPORTANT NOTE:

    Do not attempt to restart the unit in Cooling mode for at
    least three minutes after any of these actions:

 

• 

Turning the unit OFF

 

• 

Resetting the Temperature Control to a Warmer 

   position

 

• 

Switching from Cooling mode to any other mode

 A 

 B 

 88" 

 C 

 D 

 E 

 62 12 " 

CASING

CHASSIS

WITH FILTER

ACCESS PANEL

WITH HINGED

DOOR

STEEL DOUBLE

DEFLECTION 

GRILLE

REVISIONS

REV.

DESCRIPTION

BY

DATE

01

8/19/2013

A

B

C

D

E

VHPW09-15

16

17

18 7/8 18 3/8 41 3/8

VHPW18-24

18

20

20 7/8 21 3/8 45 1/2

VHPW30-36

22

24

24 7/8 25 3/8 45 1/2

6

4

3

2

1

SAB-9237

5

7

8

B

SAB-9237

01

-

-

Third Angle Projection

DATE:

MODEL BY:

365.34

MATERIAL:

08/16/13

VP

ICE-AIR LLC.

80 HARTFORD AVENUE

MOUNT VERNON, NY 10553

PROPRIETARY AND CONFIDENTIAL

WEIGHT (LBS):

FINISH:

 

N/A

DRAWING BY:

DATE:

TITLE:

SIZE

DWG.  NO.

REV

SCALE: NONE

UNLESS OTHERWISE SPECIFIED:

SHEET 1 OF 1

DO NOT SCALE DRAWING

V-WSHP GENERAL ASS'Y (BASIC)

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL  1/32

ANGULAR: MACH     BEND   1

TWO PLACE DECIMAL      .03

THREE PLACE DECIMAL    .015

This drawing is the intellectual property of 

Ice Air,LLC

 and 

consists of confidential data belonging solely to 

Ice Air,LLC

The sharing of this data with you does not constitute a 

license to share this data with any third party, which is 

strictly prohibited without Ice Air's prior written consent.

Summary of Contents for Vertical Stack Water Source Heat Pump

Page 1: ...Vertical Stack Water Source Heat Pump VWSHP OPERATING MAINTENANCE MANUAL World Class Comfort ...

Page 2: ...other important documents and product manuals The information contained within this Manual unless noted herein applies to all ICE AIR WSHP models If your unit has optional features they will be explained in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers SAFETY WARNI...

Page 3: ...rant system This system must not be opened or tampered with and any refrigeration system repairs MUST be carried out by trained technicians Refrigerant must be properly handled and recycled per EPA regulations and guidelines Your ICE AIR unit must be properly installed and commissioned to operate correctly Improper unit installation adjustment or commissioning and or improper piping installation a...

Page 4: ...tly and have dual element class RK5 fuses or HACR circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless other wise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not ...

Page 5: ...AUTO settings The thermostat has an LCD display with temperature set point s mode and status indication The temperature indication is selectable for ºF or ºC The thermostat provides permanent memory of set point s without batteries The thermostat provides a convenient override feature to temporarily change set point s OPERATING INSTRUCTIONS OPERATION IMPORTANT NOTE Do not attempt to restart the un...

Page 6: ...ur unit To remove unit slide it out towards you To reinstall place filter under the unit and slide back in to the filter rack Filter Cleaning To clean your filter use luke warm water with a biodegradable cleaner rinse and allow to dry completely before installing back to unit As an alternate cleaning method the filter may be cleaned on both sides using a vacuum cleaner with a soft brush type attac...

Page 7: ...carried out within an apartment If the coil requires additional cleaning the unit must be removed from the wall cabinet and cleaned using compressed air and or washed These operations MUST be carried out in a facility properly equipped to handle this type of work in a safe and professional manner Do not carry out this cleaning in a finished apartment or office area Drain Pan Drain Hose Cleaning Th...

Page 8: ...proper thermostat settings Check for fault codes on the control board consult the troubleshooting guide 2 If checks above fail to reveal operating problem If the unit still do not operate after reset contact trained service technician to conduct full unit diagnostics and repair to equipment Record any unit that does not operate noting the unit serial number on your report BOARD TROUBLESHOOTING TAB...

Reviews: