OPERATING & MAINTENANCE MANUAL –

 

VERTICAL STACK WATER SOURCE HEAT PUMP (VWSHP)

2

WELCOME

Congratulations on your selection of ICE AIR Water Source 
Heat Pumps (WSHPs)

 for your comfort conditioning requirements.  

WSHP units are combination cooling and heating units which 
provide an efficient, room-by-room source for comfort 
conditioning of your living environment. 

ICE AIR WSHP

 units are built to a high standard of quality and 

reliability, employing commercial grade components and heavy 
duty, galvanized sheet metal casings. With proper maintenance 
and usage,

 ICE AIR WSHPs

 should provide many years of 

efficient, quiet and trouble-free comfort.

To enhance the use of your 

ICE AIR

 equipment, you will want to 

read and carefully follow all of the instructions contained in this 
Operating & Maintenance Manual. We recommend that you pay 
special attention to the Safety and Warning Information section 
at the beginning of this Manual, and to the various safety 
advisories throughout this Manual.

Please retain this Manual for your future reference. We suggest 
that you retain it with other important documents and product 
manuals. The information contained within this Manual, unless 
noted herein, applies to all 

ICE AIR WSHP

 models. If your unit 

has optional features, they will be explained in a separate 
instruction sheet specific to that option.
 
On behalf of 

ICE AIR

, and our network of distributors and dealers, 

we are happy to welcome you to our base of satisfied customers!

SAFETY WARNINGS:

• 

Must be installed by qualified, trained installation 
personnel

• 

Must be installed in accordance with Ice Air installation 
manual and procedures

• 

Must be serviced by qualified, trained personnel

• 

Must be operated with all chassis sheet metal parts 
properly in place

• 

Must be operated with all enclosure (cabinet) parts in 
place

• 

Intended for indoor use only

• 

Electric shock hazard – disconnect from live electric 
circuit before servicing

• 

Moving parts hazard – disconnect from live electric 
circuit before servicing

• 

Read this entire operations manual before operating 
the unit

• 

Must be operated on a dedicated single circuit with 
proper electrical overcurrent protection

CONSUMER REFERENCE INFORMATION

LOCATION    

 

   MODEL NUMBER    

 

     SERIAL NUMBER

Living Room

Master Bedroom

Bedroom

Dining Room

We recommend that you 

record the following 

information about your 

Ice Air WSHP products:

Summary of Contents for Vertical Stack Water Source Heat Pump

Page 1: ...Vertical Stack Water Source Heat Pump VWSHP OPERATING MAINTENANCE MANUAL World Class Comfort ...

Page 2: ...other important documents and product manuals The information contained within this Manual unless noted herein applies to all ICE AIR WSHP models If your unit has optional features they will be explained in a separate instruction sheet specific to that option On behalf of ICE AIR and our network of distributors and dealers we are happy to welcome you to our base of satisfied customers SAFETY WARNI...

Page 3: ...rant system This system must not be opened or tampered with and any refrigeration system repairs MUST be carried out by trained technicians Refrigerant must be properly handled and recycled per EPA regulations and guidelines Your ICE AIR unit must be properly installed and commissioned to operate correctly Improper unit installation adjustment or commissioning and or improper piping installation a...

Page 4: ...tly and have dual element class RK5 fuses or HACR circuit breaker for branch circuit overcurrent protection Consult the unit serial plate for current ratings All 208 230V units are wired for 208V operation unless other wise specified The following physical conditions must be maintained for proper unit operation Unobstructed air flow into and out of the unit room enclosure cabinet Therefore Do not ...

Page 5: ...AUTO settings The thermostat has an LCD display with temperature set point s mode and status indication The temperature indication is selectable for ºF or ºC The thermostat provides permanent memory of set point s without batteries The thermostat provides a convenient override feature to temporarily change set point s OPERATING INSTRUCTIONS OPERATION IMPORTANT NOTE Do not attempt to restart the un...

Page 6: ...ur unit To remove unit slide it out towards you To reinstall place filter under the unit and slide back in to the filter rack Filter Cleaning To clean your filter use luke warm water with a biodegradable cleaner rinse and allow to dry completely before installing back to unit As an alternate cleaning method the filter may be cleaned on both sides using a vacuum cleaner with a soft brush type attac...

Page 7: ...carried out within an apartment If the coil requires additional cleaning the unit must be removed from the wall cabinet and cleaned using compressed air and or washed These operations MUST be carried out in a facility properly equipped to handle this type of work in a safe and professional manner Do not carry out this cleaning in a finished apartment or office area Drain Pan Drain Hose Cleaning Th...

Page 8: ...proper thermostat settings Check for fault codes on the control board consult the troubleshooting guide 2 If checks above fail to reveal operating problem If the unit still do not operate after reset contact trained service technician to conduct full unit diagnostics and repair to equipment Record any unit that does not operate noting the unit serial number on your report BOARD TROUBLESHOOTING TAB...

Reviews: