ICCONS
®
GAS TOOL GT-6 & GT-6ST USER MANUAL
12
March 2017 revision 1
SYMPTOM 2
Tool operates, but no fastener is driven.
Possible reasons
Services
Fastener strip
may be binding.
Use only fasteners meeting
designated specifications.
Follower holding
wrong at the top
of the pin strip.
Slide follower holder gently
to the bottom and release
to reset the pin strip in the
magazine.
Jammed fasteners
Clear jam according to User
Manual.
SYMPTOM 3
Operation of the tool is not stable.
Possible reasons
Services
Fuel Cell is low.
Replace fuel cell according
to User Manual.
Spark Plug wire is
loose.
Contact authorized service
agent for repair.
Filter element
is dirty,
causing tool to
overheat.
Remove filter element and
clean according to User
Manual.
Tool sleeve or
O-Rings are dirty.
Contact authorized service
agent for repair.
SYMPTOM 4
Unstable performance.
Possible reasons
Services
Built-up dirt and
debris inside
cylinder
Contact authorized service
agent for repair.
SYMPTOM 5
Diminishing power.
Possible reasons
Services
Damaged piston
or cylinder.
Contact authorized service
agent for repair.
5.5 Returning/Purging Stage of
Operation
SYMPTOM 1
Tool operated and drove fastener, but piston did
not return to up position.
Possible reasons
Services
Mushrooming of
Piston Tip.
Contact authorized service
agent for repair.
Exhaust ports on
the sleeve are
dirty or clogged
Contact authorized service
agent for repair.
Tool (Sleeve) or
O-Rings are dirty.
Contact authorized service
agent for repair.
SYMPTOM 2
Combustion Chamber does not drop after tool
cycles.
Possible reasons
Services
Contact arm is
bent, or tool is
dirty.
Clean tool or replace
contact arm as require