Icare HOME

Icare HOME

15.  SYMBOLS

16.  ELECTROMAGNETIC DECLARATION

Caution

See operating 

instructions for more 

information

BF-type device

Single-use disposable

Serial number

Use by <date>

Manufacturer

Keep dry

Manufacturing date

Lot number

Sterilized using irradiation

Stand by

Do not discard this product 

with other household-type 

waste. Send to appropriate 

facility for recovery 

and recycling. EU WEEE 

(European Union Directive 

for Waste of Electronic and 

Electrical Equipment)

SN

STERILE    R

LOT

Guidance and manufacturer’s declaration–Electromagnetic emissions

Icare HOME is intended for use in the electromagnetic environment specified below. 

The user of the Icare HOME should assure that it is used in such an environment.

RF emissions CISPR 11

Group 1

Icare HOME is battery operated and use RF energy only for its internal 

function. Therefore, its RF emissions are low and are not likely to cause 

any interference in nearby equipment.

RF emissions CISPR 11

Class B

Icare HOME is suitable for use in all establishments, including domestic 

establishments and those directly connected to public low-voltage power 

supply network that supplies buildings used for domestic purposes.

Guidance and manufacturer’s declaration–Electromagnetic immunity

Icare HOME is intended for use in the electromagnetic enviroment specified below. 

The customers or users of Icare HOME should assure that it is used in such enviroment.

Immunity test

IEC 60601 Test 

level

Compliance 

level

Electromagnetic environment-Guidance

Electrostatic discharge (ESD) IEC 

61000-4-2

± 6 kV contact

±8 kV air

Complies

Floors should be wood, concrete or ceramic tile. 

If floors are covered with synthetic material, the 

relative humidity should be at least 30%.

Power frequency (50/60 Hz)

magnetic field IEC 61000-4-8

3 A/m

Complies

Power frequency magnetic fields should be at 

levels characteristic of a typical location in a 

typical commercial or hospital environment.

Icare HOME is class B equipment and needs special precautions regarding EMC and 

needs to be installed and put into service according to EMC information provided 

below.

Icare HOME tonometer Instruction manual for health care professionals

Icare HOME tonometer Instruction manual for health care professionals

English

English

Summary of Contents for Icare HOME TA022

Page 1: ...HOME INSTRUCTION MANUAL FOR HEALTH CARE PROFESSIONALS ENGLISH...

Page 2: ...modification of this equipment is allowed WARNING Use only the original and certified probes made by the manufacturer The probes are for single use single pair of measurement sequences only Use probes...

Page 3: ...arby devices for example sensitive sensors If you do not use the tonometer for a long time remove the batteries as they may leak Be sure to dispose of the single use probes properly for example in a c...

Page 4: ...rly for damage to the case If you suspect that there is something wrong with the tonometer contact the dealer who sold the tonometer to you The package contains Icare HOME tonometer 10 sterilized sing...

Page 5: ...re turned on briefly Following a brief pause the Load light flashes on the back panel to remind the user to load the single use probe into the tonometer prior to measurement 6 3 LOADING THE PROBE WARN...

Page 6: ...ach of the six measurements to obtain the final IOP reading see figure left Series mode press the measurement button constantly Single mode press the measurement button briefly 1 second for each of th...

Page 7: ...forehead and cheek supports with adjustment wheels 7 3 AUTOMATIC EYE RECOGNITION NOTE Do not cover the eye recognition transmitters or sensor during the measurement for example with your fingers Keep...

Page 8: ...sition Incorrect measurement position Incorrect head and eye position Incorrect measurement position 5 Press the measurement button Single mode Press the button briefly 1 second and you hear a short b...

Page 9: ...message a Set the correct distance 4 8mm 5 32 5 16 between the probe tip and the center of the cornea b Set the probe perpendicular to the center of the cornea Repeat light is flashing and Probe base...

Page 10: ...At the same time the probe base light flashes red and you hear two short beeps The reason is either too much deviation in your measurement or the automatic eye recognition system could not recognize...

Page 11: ...the tonometer Explain that the measurement button must be depressed to obtain the sequence of 6 measurements until a long beep is heard and the green Done light is illuminated on the back panel The pr...

Page 12: ...certified prior to performing self tonometry STEP 1 Instruct the patient 1 Show and explain the tonometer s user interface including icons and status indicators Off no lights no signals Press power b...

Page 13: ...strate measurements from your HCP s own eye 1 Position the tonometer on your HCP own eye as instructed above 2 Ask the patient to observe and learn STEP 3 Supervised patient use of the icare home 1 Lo...

Page 14: ...strictions for professional use include Medivac vehicles or similar where vibration or noise levels are so high that the user cannot hear error signals Environmental restrictions for lay operators pat...

Page 15: ...in all establishments including domestic establishments and those directly connected to public low voltage power supply network that supplies buildings used for domestic purposes Guidance and manufact...

Page 16: ...he location in which the Icare HOME is used exceeds the applicable RF compliance level above the Icare HOME should be observed to verify normal operation If abnormal performance is observed additional...

Page 17: ...www icaretonometer com 32 Icare HOME www icaretonometer com HOME Icare HOME tonometer Instruction manual for health care professionals English...

Reviews: