8
AfiMilk MPC
Installation Manual
Repeat measurement procedure at each milking point.
7.2.3
Default G and H parameters per air intake
The table shows the default
G
and
H
parameters according to measured air admission in the
cluster.
Air Admission in the
Cluster
(Liters per minute)
G value for calibration
H value for
calibration
6
–7
40
30
7
–8
46
37
8
–10
49 (default)
40
11
–13
55
46
14
–17
60
50
18
–20
65
55
To adjust
G
and
H
parameters follow the procedure in paragraph
or via the AfiControl interface mentioned in paragraph
and/or H parameter value via communication
7.2.4
Adjusting G and/or H parameter value
o
Ensure that
Afimilk MPC
is in wash mode
(
wash LED illuminated
).
o
Type
2580
and press
to access programming mode.
o
Press Group access number
4
to enter Calibration Group.
G
is the first
parameter in the group and its value will appear after a short delay.
o
Press
-
G
flashes indicating that editing is enabled. Type the desired
value.
o
Press
to confirm.
o
Scroll down to the second parameter in the group
–
H
and change its value in
the same manner as explained above.