5
AfiMilk MPC
Installation Manual
Operating (top) electrode:
Connect the 100Ω resistor between the Operating (top) electrode and the Common (lower)
electrode.
1.
Press
.
2.
H###
is displayed (
###
represents the calibration value).
3.
Press
a second time to calibrate the electrode.
AdJt
appears.
4.
The electrodes have been calibrated.
5.
Press
to exit editing mode.
7.1.1.2
Reviewing Calibrated Values of Electrodes
If a milk meter fault leads to a suspected calibration problem, the technician may check
calibration value at the display:
1.
Ensure that
Afimilk MPC
is in wash mode
(
wash LED illuminated
).
2.
Type
2580
and press
to access programming mode.
3.
Press Group access number -
4
to enter Calibration Group
4.
Scroll down to
oA
(Operating Electrode).
5.
oA##
is displayed. (
##
represents the calibration value.) If the resulting value is less
than
17
or more than
34
, electrode calibration is required.
6.
Press
to scroll to calibration value
oH
(Holding Electrode).
oH##
is displayed. (
##
represents the calibration value.) If the resulting value is less
than
17
or more than
33
, electrode calibration is required.
7.
Press
(double press) to return to wash mode.
7.2
Air intake compensation
Milking clusters are manufactured with orifices allowing admission of air for improving
milk flow inside the milking system tubing. Air intake of these orifices generally varies
+