F I R E P R O T E C T I O N
(Applicable only where local ordinance permits use of this alarm control panel for fire protection.)
Fire-Zone Alarm*
If a fire is detected, "FIRE ALARM" will be displayed and the keypad sounder will pulse. In
addition, the "System Trouble" icon will flash.
1.
If a fire is in progress, evacuate the premises immediately! If necessary, call the Fire
Department from an outside phone.
2.
Tap the
C
button to silence the keypad sounder.
3.
If there is no evidence of a fire, enter your User Code and tap
U
to turn off the alarm.
4.
Check smoke detector(s). If a smoke detector tripped, its red alarm indicator light will
be on.
After the alarm condition is corrected (thermostat cooled down; smoke cleared from
detector; etc.), tapping
C
again will reset the keypad within about 10 seconds.
NOTE:
When the Fire Zone is reset, the FIRE icon on the left side of the display will go out.
If the FIRE icon is still displayed, the fire zone has not been properly reset. If you cannot
clear this condition by tapping
C
, call for service.
Fire-Zone Trouble*
1.
If a problem in the fire-circuit is detected, "FIRE TROUBLE" and the Zone number will
display and the sounder will pulse to signal a malfunction. The "System Trouble" icon
will flash, and the audible message "System has detected trouble condition" will
sound.
2.
Tap
C
to silence the sounder. Call for service immediately!
FIRE
F I R E A L A R M
F I R E T R O U B L E
*Exact messages and behavior varies depending on control panel.