Error
code
Description
Action
166-400-000
ISMP
Self
Test
Result
failed
tests:
xxx
where
xxx=flash,
ROM,
or
RAM.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Update
the
BMC
firmware
(see
3.
Reseat
the
I/O
board.
4.
Replace
the
I/O
board.
166-400-100
DMC
Self
Test
Result
failed
tests:
xxx
where
xxx=flash,
ROM,
or
RAM.
1.
Disconnect
all
server
and
option
power
cords
from
the
server,
wait
30
seconds,
reconnect
the
power
cords,
and
retry.
2.
Update
the
BIOS
code,
BMC,
service
processor,
and
diagnostics
firmware
(see
180-197-000
SCSI
ASPI
driver
not
installed.
1.
Remove
the
RAID
adapter,
if
one
is
installed,
and
run
the
test
again.
2.
Reseat
the
following
components:
a.
SAS
hard
disk
drive
backplane
cables
b.
I/O
board
c.
Microprocessor
tray
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
SAS
hard
disk
drive
backplane
b.
I/O
board
c.
(Trained
service
technician
only)
Microprocessor
tray
180-361-003
Failed
fan
LED
test.
1.
Reseat
the
following
components:
a.
Fan
b.
I/O
board
2.
Replace
the
components
listed
above
one
at
a
time,
in
the
order
listed
above,
restarting
the
server
each
time.
180-xxx-000
Diagnostics
LED
failure.
Run
the
diagnostic
LED
test
for
the
failing
LED.
Chapter
2.
Diagnostics
83
Summary of Contents for xSeries 366
Page 1: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 8: ...vi IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 28: ...12 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 160: ...144 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 170: ...154 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 181: ...V video connector 6 VRM LED 64 W Web site 1 weight 3 World Wide Web 1 Index 165...
Page 182: ...166 IBM xSeries 366 Type 8863 Problem Determination and Service Guide...
Page 183: ......
Page 184: ...Part Number 31R1508 Printed in USA 1P P N 31R1508...