Table 17. Error codes on the Single-character Display (continued)
Error Code
Cause and Action
Problems with Writing Data
If the problem occurred while the tape drive was writing data to the tape, retry the operation with
a different cartridge:
v
If the operation succeeds, the original cartridge was defective. Copy data from the defective
cartridge and discard it.
v
If the operation fails and another tape drive is available, insert the cartridge into the other unit
and retry the operation.
– If the operation fails, discard the defective cartridge.
– If the operation succeeds, insert a scratch data cartridge into the first unit and run “Function
code 1: Run drive diagnostics” on page 24.
- If the diagnostic tests fail, replace the tape drive.
- If the diagnostic tests succeed, the error was temporary.
v
If the operation fails and another tape drive is not available, insert a scratch data cartridge into
the unit and run “Function code 1: Run drive diagnostics” on page 24.
– If the diagnostic tests fail, replace the tape drive.
– If the diagnostic tests succeed, discard the cartridge.
If the problem occurs with multiple tape cartridges, run “Function code 1: Run drive diagnostics”
on page 24:
v
If the diagnostic tests fail, replace the tape drive.
v
If the diagnostic tests succeed, run“Function code H: Test head” on page 31.
– If the diagnostic test fails, replace the tape drive.
– If the diagnostic test succeeds, replace the cartridges that caused the problem.
The error code clears when you remove the tape cartridge or place the tape drive in Maintenance
mode.
Problems with Reading Data
If the problem occurred while the tape drive was reading data from the tape, complete one of
these procedures:
v
If another tape drive is available, insert the cartridge into the other unit and retry the operation:
– If the operation fails, discard the defective cartridge.
– If the operation succeeds, insert a scratch data cartridge into the first unit and run “Function
code 1: Run drive diagnostics” on page 24:
- If the diagnostic test fails, replace the tape drive.
- If the diagnostic test succeeds, the error was temporary.
v
If another tape drive is not available, insert a scratch data cartridge into the unit and run
“Function code 1: Run drive diagnostics” on page 24:
– If the diagnostic test fails, replace the tape drive.
– If the diagnostic test succeeds, discard the cartridge.
If the problem occurs with multiple tape cartridges, run “Function code 1: Run drive diagnostics”
on page 24.
v
If the diagnostic test fails, replace the tape drive.
v
If the diagnostic test succeeds, run “Function code H: Test head” on page 31.
– If the diagnostic test fails, replace the tape drive.
– If the diagnostic test succeeds, replace the cartridges that caused the problem.
The error code clears when you remove the tape cartridge or place the tape drive in Maintenance
mode.
Appendix A. Error codes and messages
67
Summary of Contents for TS2280
Page 1: ...IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S SC27 4649 00 IBM...
Page 2: ......
Page 4: ...iv IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 6: ...vi IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 10: ...x IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 12: ...xii IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 20: ...xx IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 22: ...xxii IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 58: ...36 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 80: ...58 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 86: ...64 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 94: ...72 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 100: ...78 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 104: ...82 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 126: ...104 IBM TS2280 Setup Operator and Service Guide Machine Type 3580 Model H8S...
Page 141: ......
Page 142: ...IBM Part Number 01PL139 Printed in USA SC27 4649 00 1P P N 01PL139...