Updating
the
Firmware
with
an
FMR
Tape
Cartridge
Attention:
SCSI
drives
and
Fibre
Channel
drives
require
different
firmware
images.
Tip
After
creating
an
FMR
tape
(see
“Function
Code
3:
Create
FMR
Tape”
on
page
35),
the
firmware
of
multiple
drives
can
be
updated
with
the
same
FMR
tape.
After
updating
the
drive
firmware,
unmake
the
FMR
tape
(see
“Function
Code
8:
Unmake
FMR
Tape”
on
page
38)
and
use
it
as
a
data
cartridge.
To
update
the
drive’s
firmware
from
an
FMR
tape
cartridge:
1.
Ensure
that
a
cartridge
is
not
loaded
in
the
drive.
2.
Place
the
drive
in
maintenance
mode
by
pressing
the
Unload
Button
three
times
within
a
two
seconds.
The
Status
Light
becomes
solid
amber,
which
means
that
the
drive
is
in
maintenance
mode.
3.
Press
the
Unload
Button
once
per
second
until
8
displays,
then
press
and
hold
the
button
for
three
seconds.
When
C
flashes,
the
drive
is
waiting
for
a
cartridge.
4.
Insert
the
FMR
tape
cartridge.
8
flashes,
the
drive
loads
the
updated
firmware
from
the
cartridge,
and
the
Status
Light
flashes
amber.
When
the
update
completes
successfully,
0
displays
and
the
cartridge
automatically
ejects.
The
drive
resets
itself
and
automatically
activates
the
new
firmware.
If
the
update
fails,
an
error
code
displays.
To
resolve
the
error,
locate
the
code
in
Table
15
on
page
75.
50
IBM
TotalStorage
Ultrium
Tape
Drive
Summary of Contents for TotalStorage Ultrium T800
Page 2: ......
Page 8: ...vi IBM TotalStorage Ultrium Tape Drive...
Page 10: ...viii IBM TotalStorage Ultrium Tape Drive...
Page 14: ...xii IBM TotalStorage Ultrium Tape Drive...
Page 16: ...xiv IBM TotalStorage Ultrium Tape Drive...
Page 28: ...12 IBM TotalStorage Ultrium Tape Drive...
Page 88: ...72 IBM TotalStorage Ultrium Tape Drive...
Page 108: ...92 IBM TotalStorage Ultrium Tape Drive...
Page 124: ...108 IBM TotalStorage Ultrium Tape Drive...
Page 126: ...110 IBM TotalStorage Ultrium Tape Drive...
Page 130: ...114 IBM TotalStorage Ultrium Tape Drive...
Page 147: ......
Page 148: ...Printed in USA GC26 7697 01...