Table 9. POST error messages (continued)
POST message
Description
11xx
An error occurred during the system-board serial port test.
Action: If you have a modem, serial printer, or other serial device attached to your appliance,
verify that the serial cable is connected correctly. If it is, use the following procedure:
1. Turn off the appliance.
2. Disconnect the serial cable from the serial port.
3. Wait five seconds; then, turn on the appliance.
If the POST error message does not reappear, either the serial cable or the device is probably
failing. See the documentation that comes with the serial device for additional testing
information.
If the POST error message reappears, call for service.
1162
The serial port configuration conflicts with another device in the system.
Action:
1. Make sure the IRQ and I/O port assignments needed by the serial port are available.
2. If all interrupts are being used by adapters, you might need to remove an adapter to make
an interrupt available to the serial port, or force other adapters to share an interrupt.
1301
Cable to Information LED panel not detected.
Action: Make sure that the cable to the operator information panel is connected.
If the problem persists, call for service.
1302
Cable to Power and Reset push-buttons not detected.
Action: Make sure that the cable to the Power and Reset push-buttons is connected.
If the problem persists, call for service.
1303
I2C cable to Power Backplane not detected.
Action: Make sure that the cable to the power backplane is connected.
If the problem persists, call for service.
1304
Cable to Diagnostic LED panel not detected.
Action: Make sure that the cable to the diagnostic LED panel is connected.
If the problem persists, call for service.
1600
The Netfinity Advanced System Management processor is not functioning.
Action:
1. Verify that the jumpers for the system-management processor are set correctly.
2. Disconnect the appliance from all electrical sources, wait for 30 seconds, reconnect the
appliance to the electrical sources, and restart the appliance.
If the problem persists, call for service.
1601
The BIOS needs to be updated.
Action:
1. Disconnect the appliance from all electrical sources, wait for 30 seconds, reconnect the
appliance to the electrical sources, and restart the appliance.
2. If the problem persists, update the BIOS.
If the problem persists, call for service.
1800
A PCI adapter has requested a hardware interrupt that is not available.
Action:
1. Make sure that the PCI adapter and all other adapters are set correctly in the
Configuration/Setup Utility program. If the interrupt resource settings are not correct,
change the settings.
2. If all interrupts are being used by other adapters, you might need to remove an adapter to
make an interrupt available to the PCI adapter, or force other adapters to share an
interrupt.
58
300G User’s Reference
Summary of Contents for TotalStorage Network Attached Storage 300G
Page 1: ...TotalStorage Network Attached Storage 300G User s Reference V ersion 1 Release 1 GA27 4271 00...
Page 2: ......
Page 3: ...TotalStorage Network Attached Storage 300G User s Reference V ersion 1 Release 1 GA27 4271 00...
Page 8: ...vi 300G User s Reference...
Page 10: ...viii 300G User s Reference...
Page 14: ...2 300G User s Reference...
Page 32: ...20 300G User s Reference...
Page 38: ...26 300G User s Reference...
Page 62: ...50 300G User s Reference...
Page 85: ......