Table
14.
Diagnostic
and
maintenance
functions
(continued)
Function
Code
Diagnostic
or
Maintenance
Function
Instructions
Location
J
Fast
Read/Write
Test:
Performs
tests
to
ensure
that
the
drive
can
read
from
and
write
to
tape.
Page
80
L
Load/Unload
Test:
Tests
the
drive’s
ability
to
load
and
unload
a
tape
cartridge.
Page
81
P
Enable
Post
Error
Reporting:
When
selected,
deferred-check
conditions
are
reported
to
the
host.
Page
82
U
Disable
Post
Error
Reporting:
When
selected,
deferred-check
conditions
are
NOT
reported
to
the
host.
Page
82
Entering
Maintenance
Mode
The
drive
must
be
in
maintenance
mode
to
run
drive
diagnostics
or
maintenance
functions.
To
place
the
unit
in
maintenance
mode:
1.
Make
sure
that
no
cartridge
is
in
the
drive.
2.
Press
the
Unload
Button
three
times
within
two
seconds.
0
appears
in
the
Single-character
Display
(SCD),
and
the
Status
Light
turns
amber.
Note:
If
a
cartridge
is
in
the
tape
drive,
it
will
eject
the
first
time
that
you
press
the
Unload
Button
and
the
drive
will
not
be
placed
in
maintenance
mode.
To
continue
placing
the
drive
in
maintenance
mode,
perform
the
preceding
step.
Maintenance
functions
cannot
be
performed
concurrently
with
read
or
write
operations.
While
in
maintenance
mode,
the
drive
does
not
receive
SCSI
commands
from
the
server.
Function
Code
0:
Exit
Maintenance
Mode
Function
Code
0
makes
the
drive
available
for
reading
and
writing
data.
1.
Place
the
drive
in
maintenance
mode.
For
instructions,
see
“Entering
Maintenance
Mode.”
2.
Press
and
hold
the
Unload
Button
for
three
or
more
seconds
to
take
the
drive
out
of
maintenance
mode.
The
Status
Light
turns
off.
v
If
no
error
is
detected,
0
temporarily
appears
in
the
SCD,
then
goes
blank.
The
drive
then
exits
maintenance
mode.
v
If
an
error
is
detected,
the
SCD
shows
an
error
code
but
still
exits
maintenance
mode.
To
determine
the
error,
locate
the
code
in
Table
13
on
page
61.
To
clear
the
error,
turn
the
power
off,
then
on
again.
The
drive
also
exits
maintenance
mode
automatically
after
it
completes
a
maintenance
function
or
after
ten
minutes
if
no
action
has
occurred.
68
IBM
TotalStorage
3580
Tape
Drive
Setup,
Operator,
and
Service
Guide
Summary of Contents for TotalStorage 3580 L33
Page 1: ...IBM TotalStorage 3580 Tape Drive Model L33 L3H Setup Operator and Service Guide GC26 7708 03...
Page 2: ......
Page 3: ...IBM TotalStorage 3580 Tape Drive Model L33 L3H Setup Operator and Service Guide GC26 7708 03...
Page 6: ...iv IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 10: ...viii IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 12: ...x IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 47: ...A67E0026 1 Figure 11 Setting the write protect switch Using Ultrium Media 29...
Page 72: ...54 IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 84: ...66 IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 102: ...84 IBM TotalStorage 3580 Tape Drive Setup Operator and Service Guide...
Page 141: ......
Page 142: ...Part Number 23R6251 Printed in USA GC26 7708 03 1P P N 23R6251...