v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 4, “Parts listing, System x3100 M4 Type 2582,” on page 151 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
Action
0068002
CMOS battery cleared.
1. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2. Replace the CMOS battery (see “Removing the
system battery” on page 207 and “Installing the
system battery” on page 209).
3. (Trained service technician only) Replace the
system board (see“Removing the system board”
on page 258 and “Installing the system board” on
page 261).
0068005
IOH or IIO has reported an error.
1. Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory error.
2. Replace the following components one at a time
in the order shown, restarting the server each
time:
v
PCI Express adapter (see “Removing a
ServeRAID adapter” on page 176 and
“Installing a ServeRAID adapter” on page 178).
v
(Trained service technician only) System board
(see“Removing the system board” on page 258
and “Installing the system board” on page 261).
2011000
PCI PERR.
1. Check the riser-card LEDs.
2. Reseat all affected adapters and riser cards.
3. Update the PCI adapter firmware.
4. Replace the affected adapters and riser cards
(see “Removing a ServeRAID adapter” on page
176 and “Installing a ServeRAID adapter” on page
178).
5. (Trained service technician only) Replace the
system board (see“Removing the system board”
on page 258 and “Installing the system board” on
page 261).
Chapter 3. Diagnostics
35
Summary of Contents for System x3100 M4
Page 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 331: ......
Page 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...