10. Select
Select Drives
and use space key to select all the drives for your array.
11. Select
Apply Change
to create the array.
12. When the prompt
Success
is displayed, select
OK
to continue.
13. After the system auto skip to the next screen, select
Save Configuration
.
14. When the prompt
create RAID will cause data lost on the physical HDD
is
displayed, use space key to select
Confirm
.
15. Select
Yes
to continue.
16. Select
OK
to continue.
17. To initialize virtual disk, select
LSI MegaRAID Controller Configuration
Utility
→
Virtual Drive Management
→
Select Virtual Drive Operation
.
18. Select
Start Operation
.
19. Select
Yes
to confirm.
20. When the prompt
Success
is displayed, select
OK
.
Notes:
1. Software RAID is not supported in Redhat 6.1 UEFI mode.
2. You can create software RAID with Linux OS RAID. LSI software RAID is turned
off in Linux OS by default.
3. Legacy OS installation is not supported when BBS boot is enabled on
ServeRAID M5014.
4. Brocade adapters are supported in Windows 2011 SBS with 3.0.0.0 driver
package or later version installed.
Disable a software RAID array of hard disk drives
To disable a software RAID array of hard disk drives, complete the following steps.
1. Turn on the server.
Note:
Approximately 1 to 3 minutes after the server is connected to ac power,
the power-control button becomes active after the power-on LED flashes slowly.
2. When the prompt
<F1 Setup>
is displayed, press F1. If you have set an
administrator password, you are prompted to type the password.
3. Select
Devices and I/O Ports
→
Adapters and UEFI drivers
.
4. Save the setting and reboot the system.
5. Press F1 to boot the uEFI setup menu.
6. Select
Devices and I/O Ports
→
Configure SATA as
.
7. Select
IDE
or
AHCI
.
8. Save the setting and
reboot the system
.
IBM Advanced Settings Utility program
The IBM Advanced Settings Utility (ASU) program is an alternative to the Setup
utility for modifying UEFI settings. Use the ASU program online or out of band to
modify UEFI settings from the command line without the need to restart the system
to access the Setup utility.
In addition, the ASU program provides limited settings for configuring the IPMI
function in the IMM2 through the command-line interface.
Use the command-line interface to issue setup commands. You can save any of the
settings as a file and run the file as a script. The ASU program supports scripting
environments through a batch-processing mode.
Chapter 6. Configuration information and instructions
285
Summary of Contents for System x3100 M4
Page 1: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 24: ...4 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 42: ...22 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 170: ...150 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 182: ...162 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 286: ...266 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 316: ...296 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 324: ...304 IBM System x3100 M4 Type 2582 Problem Determination and Service Guide...
Page 331: ......
Page 332: ...Part Number 00V9701 Printed in USA 1P P N 00V9701...