DS4300
storage
server
operating
specifications
Size
(with
front
panel
and
without
mounting
rails)
v
Depth:
59.7
cm
(23.6
in.)
v
Height:
13.2
cm
(5.2
in.)
v
Width:
48
cm
(18.9
in.)
Heat
output
v
390
watts
(1330
BTU/hr)
Weight
v
Standard
storage
server
as
shipped:
–
Model
60U/60X:
39.10
kg
(86.2
lb)
–
Model
6LU/6LX:
34.34
kg
(75.7
lb)
v
Unit
weight:
–
Model
60U/60X:
31.48
kg
(69.4
lb)
–
Model
6LU/6LX:
26.71
kg
(58.9
lb)
Electrical
input
v
Sine-wave
input
(50
to
60
Hz)
is
required
v
Input
voltage:
–
Low
range:
-
Minimum:
90
V
ac
-
Maximum:
136
V
ac
–
High
range:
-
Minimum:
198
V
ac
-
Maximum:
264
V
ac
–
Input
kilovolt-amperes
(kVA)
approximately:
-
Minimum
configuration:
0.06
kVA
-
Maximum
configuration:
0.37
kVA
Environment
v
Air
temperature:
–
Storage
server
on:
10°
to
35°
C
(50°
to
95°
F)
Altitude:
0
to
914
m
(3000
ft.)
–
Storage
server
on:
10°
to
32°
C
(50°
to
90°
F)
Altitude:
914
m
(3000
ft.)
to
2133
m
(7000
ft.)
v
Humidity:
–
8%
to
80%
–
Noncondensing
Acoustical
noise
emissions
values
For
open
bay
(0
drives
installed)
and
typical
system
configurations
(14
hard
disk
drives
installed):
v
Sound
power
(idling):
–
6.3
bels
(open
bay)
–
6.5
bels
(typical)
v
Sound
power
(operating):
–
6.3
bels
(open
bay)
–
6.8
bels
(typical)
v
Sound
pressure
(idling):
–
47
dBA
(open
bay)
–
49
dBA
(typical)
v
Sound
pressure
(operating):
–
47
dBA
(open
bay)
–
53
dBA
(typical)
These
levels
are
measured
in
controlled
acoustical
environments
according
to
ISO
7779
and
are
reported
in
accordance
with
ISO
9296.
The
declared
sound
power
levels
indicate
an
upper
limit,
below
which
a
large
portion
of
machines
operate.
Sound
pressure
levels
in
your
location
might
exceed
the
average
1-meter
values
stated
because
of
room
reflections
and
other
nearby
noise.
Storage
server
components
The
following
sections
show
the
components
of
the
DS4300
storage
server.
Note:
The
graphics
used
in
this
document
are
for
illustrative
purposes
only.
The
appearance
of
the
actual
device
may
differ
from
the
graphic.
All
DS4300
storage
server
models
support
hot-swap
fibre
channel
hard
drive
CRUs
and
cooling
fan
CRUs,
so
you
can
remove
and
replace
these
components
without
turning
off
the
storage
server.
In
addition,
the
DS4300
storage
server
models
60X
and
60U
support
hot-swap
power
supplies
and
RAID
controller
CRUs.
Note:
The
DS4300
single-controller
storage
server
(model
6LU
and
6LX)
has
one
power
supply
and
one
controller;
therefore,
you
cannot
hot
swap
these
components.
Front
view
Figure
46
on
page
66
shows
the
components
and
controls
on
the
front
of
the
DS4300
storage
server.
Chapter
9.
Type
1722
DS4300
Storage
Server
65
Summary of Contents for System Storage DS4000
Page 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 183: ......
Page 184: ...Printed in USA GC26 7702 00...