LED
On
This
indicates
that
a
GBIC
is
present
and
functioning
properly.
LED
Off
This
indicates
a
fault
condition.
Examples
of
a
fault
condition
include:
a
GBIC
transmitter
fault,
an
improperly
seated
GBIC,
an
absent
GBIC,
or
another
failed
device.
The
port
will
be
in
the
bypass
state,
which
precludes
the
port
from
participating
in
the
FC-AL.
This
is
the
normal
status
of
operation
for
fibre
channel
hub
ports
in
which
GBICs
are
not
installed.
Note:
FC-AL
compatible
nodes
must
perform
loop
initialization
procedures
at
power
on
to
function
properly
on
the
loop.
FC-AL
nodes
also
perform
loop
initialization
or
reinitialization
depending
on
their
prior
state
of
operation.
4.
Check
the
Port
Bypass
(amber)
LEDs.
See
Figure
7.
LED
On
If
the
Active
(green)
LED
of
the
port
is
off,
the
port
is
nonoperational
and
the
Bypass
(amber)
LED
for
the
port
is
on.
If
a
properly
functioning
port
(the
Active
green
LED
is
on)
with
a
GBIC
present
also
has
the
Bypass
LED
on,
either
the
loss
of
signal
or
poor
signal
integrity
has
caused
the
port
to
go
into
the
bypass
state.
When
the
port
is
in
this
state,
it
cannot
participate
in
the
FC-AL.
The
bypass
state
is
also
the
normal
status
condition
when
no
GBIC
is
present
in
the
port,
a
GBIC
is
present
but
not
attached
to
a
FC-AL
node,
or
a
GBIC
is
attached
to
a
cable
assembly
with
nothing
attached
at
the
opposite
end.
Replacing
such
a
port
(or
removing
and
reinserting
the
GBIC
into
the
same
port
twice)
is
considered
to
be
a
loop
configuration
change
that
invokes
the
Loop
Initialization
Procedure.
LED
Off
This
indicates
that
the
fibre
channel
hub
port
and
device
are
fully
operational
and
actively
participating
in
the
FC-AL.
5.
The
FC-AL
should
be
fully
operational.
Check
that
proper
loop
discovery
has
taken
place
and
all
required
devices
are
participating
in
the
loop.
Some
host
bus
adapters
might
provide
this
level
of
functionality
or
it
might
be
resident
in
the
application
software
on
the
host
operating
system.
Active On
Green LEDs on Top Row
Figure
6.
Type
3523
fibre
channel
hub
active
LEDs
Bypass
Amber LEDs on Bottom Row
Figure
7.
Type
3523
fibre
channel
hub
port
bypass
LEDs
Chapter
2.
Type
3523
Fibre
Channel
Hub
and
GBIC
7
Summary of Contents for System Storage DS4000
Page 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 183: ......
Page 184: ...Printed in USA GC26 7702 00...