Chapter
5.
DS4000
FC2-133
Host
Bus
Adapter
Note:
The
PD
maps
found
in
the
IBM
TotalStorage
DS4000
Problem
Determination
Guide
provide
you
with
additional
diagnostic
aids.
The
IBM
DS4000
FC2-133
host
bus
adapter
(single
port
model,
FRU
24P0962)
is
a
2
Gbps
high-performance,
direct
memory
access
(DMA),
bus
master,
fibre
channel
host
adapter
designed
for
high-end
systems.
The
function
and
performance
are
derived
from
the
ISP2312/ISP2340
chips,
making
the
IBM
DS4000
FC2-133
host
bus
adapter
a
leading-edge
host
adapter.
The
ISP2312/ISP2340
chips
combine
a
powerful,
reduced
instruction
set
computer
(RISC)
processor,
a
fibre
channel
protocol
manager
(FPM)
with
one
2
Gbps
fibre
channel
transceiver,
and
a
peripheral
component
interconnect
(PCI)
or
peripheral
component
interconnect-extended
(PCI-X)
local
bus
interface
in
a
single-chip
solution.
The
IBM
DS4000
FC2-133
host
bus
adapter
supports
all
fibre
channel
(FC)
peripheral
devices
that
support
private-loop
direct
attach
(PLDA)
and
fabric-loop
attach
(FLA).
The
IBM
TotalStorage
DS4000
Problem
Determination
Guide
provides
detailed
configuration
information
for
advanced
users
who
want
to
use
IBM
Fast!UTIL
to
customize
the
configuration
of
the
DS4000
FC2-133
host
bus
adapter.
Note:
For
information
about
how
to
use
and
troubleshoot
problems
with
the
FC
6228
2
Gigabit
fibre
channel
adapter
in
pSeries
AIX
®
hosts,
see
Fibre
Channel
Planning
and
Integration:
User’s
Guide
and
Service
Information
,
SC23-4329-03.
General
checkout
The
following
types
of
installation
problems
might
cause
your
DS4000
FC2-133
host
bus
adapter
to
function
incorrectly:
v
Hardware
problems
v
System
configuration
problems
v
Fibre
channel
problems
If
you
are
having
problems,
use
the
following
information
to
help
you
determine
the
cause
of
the
problem
and
the
action
to
take.
Hardware
problems
Take
the
following
actions
to
determine
if
your
installation
problem
is
caused
by
the
hardware:
v
Verify
that
all
adapters
are
installed
securely.
v
Verify
that
all
cables
are
attached
securely
to
the
correct
connectors.
Be
sure
that
one
end
of
the
LC-LC
fibre
channel
cable
is
attached
to
the
optical
interface
connector
(located
at
J1
on
the
adapter)
and
that
the
other
end
is
connected
to
the
fibre
channel
device.
v
Verify
that
the
DS4000
FC2-133
host
bus
adapter
is
installed
correctly
and
is
fully
seated
in
the
expansion
slot.
Check
for
interference
due
to
nonstandard
PCI
connectors.
v
Verify
that
the
Fast!UTIL
data-rate
setting
is
correct.
The
Fast!UTIL
data-rate
setting
must
match
the
speed
of
the
device
to
which
you
are
connected.
©
Copyright
IBM
Corp.
2004
17
Summary of Contents for System Storage DS4000
Page 1: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 2: ......
Page 3: ...IBM TotalStorage DS4000 Hardware Maintenance Manual GC26 7702 00...
Page 10: ...viii IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 16: ...xiv IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 30: ...2 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 38: ...10 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 44: ...16 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 48: ...20 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 88: ...60 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 120: ...92 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 138: ...110 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 146: ...118 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 178: ...150 IBM TotalStorage DS4000 Hardware Maintenance Manual...
Page 183: ......
Page 184: ...Printed in USA GC26 7702 00...