b.
If you configured the new storage subsystem with at least two new drives
to get the storage subsystem into Optimal state for updating the controller
firmware, perform one of the following tasks:
v
Leave the new storage subsystem configuration as is. Perform steps 4c-4g,
5a or 5b, and 5c-5e to prepare the original subsystem configuration for
drive and drive enclosure migration and to turn off power of the original
storage subsystem. Use the procedure in Chapter 3, “Adding or migrating
storage enclosures,” on page 25 to migrate the drives and storage
enclosures in the original storage subsystem into the new storage
subsystem configuration. After you migrate all of the drives and storage
No
Yes
Finish
dg1dr004
No
Yes
Start
Is the version of
controller firmware
in the
subsystem
original
less than or equal to
the version of
controller firmware
in
new
subsystem?
Upgrade the controller
firmware in the
new
subsystem
to the same or
later version than the
controller firmware in the
through
original subsystem
the Storage Manager
Client GUI after first
configuring it with
two new drives.
Upgrade both the
and the
original
new DS3500, DCS3700, DCS3860,
DCS3700 with Gen2 controllers,
DCS3860 with Gen2 controllers,
or the DCS3700 Performance Module
Controllers subsystem
to the
same version of the 8.2x controller
firmware before the head-wap.
You might need to
Note:
purchase two extra drives
to upgrade the
new
storage subsystem.
Is
8.2x
the version
of the controller
firmware on the
or the
original
new
DS3500, DCS3700, DCS3860,
DCS3700 with Gen2 controllers,
DCS3860 with Gen2 controllers
or the DCS3700 Performance
Module Controllers
subsystem?
Figure 9. Firmware compatibility flowchart for a storage subsystem upgrade
Chapter 4. Upgrading a storage subsystem controller
49