Identifying Disk Drive Modules
You can identify a disk drive module by the serial number that appears on a label
«1¬
on the front of the module:
This label also shows the capacity of the disk drive.
Each disk drive module also has a FC-AL address that is related to its position in
the ProFibre Storage Array unit.
The addresses used are S0 to S9 (hex) where S is the setting of the address switch
on the switch card. These addresses are assigned, in sequence, from left to right.
Figure 12. Disk Drive Module Label
Chapter 1. Introduction
11
Summary of Contents for StorageSmart DF1100J
Page 2: ......
Page 6: ...iv ProFibre Storage Array Operator s Guide...
Page 22: ...12 ProFibre Storage Array Operator s Guide...
Page 40: ...30 ProFibre Storage Array Operator s Guide...
Page 42: ...32 ProFibre Storage Array Operator s Guide...
Page 46: ...36 ProFibre Storage Array Operator s Guide...
Page 48: ...38 ProFibre Storage Array Operator s Guide...
Page 51: ......