The serial port can be used to connect to a workstation to configure the switch IP
address before connecting the switch to a fabric or IP network. The serial port’s
parameters are fixed at 9600 baud, 8 data bits, and no parity, with flow control set
to None.
Table 20 lists the serial cable pinouts.
Table 20. Serial cable pinouts
Pin
Signal
Description
1
Not supported
N/A
2
Not supported
N/A
3
UART1_TXD
Transmit data
4
GND
Logic ground
5
GND
Logic ground
6
UART1_RXD
Receive data
7
Not supported
N/A
8
Not supported
N/A
Memory specifications
The switch has four memory devices: boot, compact flash, control plane, and data
plane memory. The size of each is listed in Table 21.
Table 21. Memory specifications
Memory name
Memory type
Memory size
Boot
Flash
4 MB
Compact flash
USB
8 GB
Control Plane
DDR3 RDIMM SDRAM
8 GB
Data Plane
DDR3 RDIMM SDRAM
128 GB
54
SAN42B-R Installation, Service, and User Guide
Summary of Contents for SAN42B-R
Page 2: ......
Page 6: ...iv SAN42B R Installation Service and User Guide...
Page 8: ...vi SAN42B R Installation Service and User Guide...
Page 10: ...viii SAN42B R Installation Service and User Guide...
Page 22: ...xx SAN42B R Installation Service and User Guide...
Page 56: ...32 SAN42B R Installation Service and User Guide...
Page 62: ...38 SAN42B R Installation Service and User Guide...
Page 72: ...48 SAN42B R Installation Service and User Guide...
Page 94: ...70 SAN42B R Installation Service and User Guide...
Page 95: ......
Page 96: ...Part Number 00MA667 Printed in USA SC27 6633 00 1P P N 00MA667...