3-1 (Page 21 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
40B00102
Surveillance timeout on CPU 3.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
40B00103
Surveillance timeout on CPU 4.
1. Check for errors or unusual
conditions that might prevent the
CPU from reporting Heartbeat
messages; such as system dump,
machine check or checkstop error.
Review the Service Processor error
log.
2. Replace the CPU card.
40D00003
An unknown slow shutdown
commanded.
Critical cooling problem. Check to
ensure the the temperature is in the
ambient range
40D00004
An unknown fast shutdown
commanded.
Locked fan failure detected. Make sure
all fans are operating normally.
4B200054
The CPU cards are not compatible with
each other (i.e. one is a 166MHz and
the other is a 332MHz)
1. Remove cards
2. Verify part numbers
3. Install valid cards
4B200055
No CPU card in first slot.
1. If only one processor card is used,
it must be in slot #1.
2. If two processor cards are being
used, replace the card in slot #1.
4B201000
Checkstop
1. Attempt to reboot the system in
Service Mode, this preserves the
AIX error log. If the reboot fails,
attempt to reboot from the
CD-ROM. If the reboot is
successful, run Diagnostics in
Problem Determination mode to
determine the cause of the failure.
Otherwise continue.
2. CPU Card.
3. System Board.
4. PCI Adapter.
5. I/O board. (See notes on 3-1.)
3-22
Service Guide
Summary of Contents for RS/6000 7025 F50 Series
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01 ...
Page 6: ...vi Service Guide ...
Page 14: ...xiv Service Guide ...
Page 16: ...xvi Service Guide ...
Page 18: ...Rear View 1 2 Service Guide ...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7 ...
Page 24: ...System Data Flow 1 8 Service Guide ...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide ...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49 ...
Page 208: ...5 40 Service Guide ...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3 ...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9 ...
Page 222: ...5 Close the door 6 14 Service Guide ...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23 ...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide ...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39 ...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43 ...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1 ...
Page 256: ...7 2 Service Guide ...
Page 278: ...A 16 Service Guide ...
Page 344: ...D 28 Service Guide ...
Page 348: ...E 4 Service Guide ...
Page 357: ...voice phone number B 20 VPD vital product data B 13 VPD vital product data 3 93 Index X 9 ...
Page 358: ...X 10 Service Guide ...
Page 361: ......