Table
3-1 (Page 12 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00012
Service processor reports self-test
failure.
1. Unplug the system power cable
and wait until the system power
indicator remains off and the
operator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the service processor
card.
4. Replace the I/O board. (See notes
2BA00013
Service processor reports bad NVRAM
CRC.
1. If problem persists, replace battery.
2. Replace the I/O board. (See notes
2BA00014
Service processor reports bad service
processor firmware.
Use service processor firmware
diskette to re-program firmware.
2BA00017
Service processor reports bad or low
battery.
1. Replace the battery.
2. Replace the service processor
card.
3. Replace the I/O board. (See notes
2BA00018
EPOW test failure.
1. Replace the service processor.
2. Replace the I/O board. (See notes
2BA00019
IRQ13 test failure.
1. Replace the I/O board. (See notes
2. Replace the service processor
card.
2BA00024
Service processor reports bad Power
Controller firmware.
Use the System Firmware diskette to
re-program the System firmware.
2BA00040
Service processor reports Service
Processor VPD module not present.
1. Use the Service Processor
Firmware diskette to re-program
the Service Processor firmware.
2. Replace the Service Processor
card.
2BA00041
Service processor VPD is corrupted.
1. Use the service processor firmware
diskette to re-program the service
processor firmware.
2. Replace the service processor
card.
2BA00050
Service processor reports system
operator panel VPD module not present
or not recognizeable.
Replace the operator panel control
assembly. (See notes on 3-1.)
Note: Swap the old VPD module from
the old operator panel control assembly
to the new one.
Chapter 3. Error Code to FRU Index
3-13
Summary of Contents for RS/6000 7025 F50 Series
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01 ...
Page 6: ...vi Service Guide ...
Page 14: ...xiv Service Guide ...
Page 16: ...xvi Service Guide ...
Page 18: ...Rear View 1 2 Service Guide ...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7 ...
Page 24: ...System Data Flow 1 8 Service Guide ...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide ...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49 ...
Page 208: ...5 40 Service Guide ...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3 ...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9 ...
Page 222: ...5 Close the door 6 14 Service Guide ...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23 ...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide ...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39 ...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43 ...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1 ...
Page 256: ...7 2 Service Guide ...
Page 278: ...A 16 Service Guide ...
Page 344: ...D 28 Service Guide ...
Page 348: ...E 4 Service Guide ...
Page 357: ...voice phone number B 20 VPD vital product data B 13 VPD vital product data 3 93 Index X 9 ...
Page 358: ...X 10 Service Guide ...
Page 361: ......