3-1 (Page 14 of 24). Firmware Error Codes.
Error Code
Description
Action / Possible Failing FRU
2BA00200
Service processor firmware update
error occurred, update not completed.
Error occurred during service processor
flash write operation.
Service processor firmware update
error recovery procedure:
1. Turn the system Off.
2. Unplug power cable and then plug
power cable back in.
3. Turn the system On.
4. Retry operation. If problem
persists, replace service processor.
2BA00201
Service processor firmware update
error occurred, update not completed.
Error occurred while reading service
processor CRC.
See error code 2BA00200 for recovery
procedure.
2BA00202
Service processor firmware update
error occurred, update not completed.
Error occurred while verifying service
processor CRC.
See error code 2BA00200 for recovery
procedure.
2BA00203
Service processor firmware update
error occurred, update not completed.
Error occurred while reading new
service processor CRC after updating
service processor firmware.
See error code 2BA00200 for recovery
procedure.
2BA00204
Service processor firmware update
error occurred, update not completed.
Error occurred while calculate CRC
write.
See error code 2BA00200 for recovery
procedure.
2BA00300
Service Processor reports Slow Fan
number 1
1. Replace Fan 1.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
2BA00301
Service Processor reports Slow Fan
number 2.
1. Replace Fan 2.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
2BA00302
Service Processor reports Slow Fan
number 3.
1. Replace Fan 3.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
Chapter 3. Error Code to FRU Index
3-15
Summary of Contents for RS/6000 7025 F50 Series
Page 1: ...RS 6000 7025 F50 Series IBM Service Guide SA38 0541 01 ...
Page 6: ...vi Service Guide ...
Page 14: ...xiv Service Guide ...
Page 16: ...xvi Service Guide ...
Page 18: ...Rear View 1 2 Service Guide ...
Page 23: ...Operator Panel Chapter 1 Reference Information 1 7 ...
Page 24: ...System Data Flow 1 8 Service Guide ...
Page 120: ...AIX and Physical Location Code Reference Table 3 48 Service Guide ...
Page 121: ...Chapter 3 Error Code to FRU Index 3 49 ...
Page 208: ...5 40 Service Guide ...
Page 211: ...Covers Removal 1 Open the door Chapter 6 Removal and Replacement Procedures 6 3 ...
Page 217: ...b Remove the I O planar cover Chapter 6 Removal and Replacement Procedures 6 9 ...
Page 222: ...5 Close the door 6 14 Service Guide ...
Page 231: ...4 Remove the screw holding the adapter Chapter 6 Removal and Replacement Procedures 6 23 ...
Page 240: ...4 Remove the Processor card s as described in Processor Card on page 6 35 6 32 Service Guide ...
Page 247: ...Chapter 6 Removal and Replacement Procedures 6 39 ...
Page 251: ...Replacement Replace in reverse order Chapter 6 Removal and Replacement Procedures 6 43 ...
Page 255: ...Chapter 7 Parts Information Chapter 7 Parts Information 7 1 ...
Page 256: ...7 2 Service Guide ...
Page 278: ...A 16 Service Guide ...
Page 344: ...D 28 Service Guide ...
Page 348: ...E 4 Service Guide ...
Page 357: ...voice phone number B 20 VPD vital product data B 13 VPD vital product data 3 93 Index X 9 ...
Page 358: ...X 10 Service Guide ...
Page 361: ......