Table 9. Slot numbers, adapter descriptions, and service action for the 8001-12C and 8005-12N
Slot information from log
PCIe adapter description
Service action
UIO Network
PCIe adapter 1
Replace the PCIe adapter indicated in
the PCIe adapter description column.
Go to “8001-12C or 8005-12N
locations” on page 73 to identify the
physical location and the removal
and replacement procedure.
UIO Slot1
PCIe adapter 2
PLX Slot1
PCIe adapter 3
WIO Slot1
PCIe adapter 4
WIO Slot2
PCIe adapter 5
Table 10. Slot numbers, adapter descriptions, and service action for the 8001-22C and 8005-22N
Slot information from log
PCIe adapter description
Service action
UIO Network
PCIe adapter 1
Replace the PCIe adapter indicated in
the PCIe adapter description column.
Go to “8001-22C or 8005-22N
locations” on page 87 to identify the
physical location and the removal
and replacement procedure.
UIO Slot2
PCIe adapter 2
UIO Slot1
PCIe adapter 3
PLX Slot1
PCIe adapter 4
WIO Slot1
PCIe adapter 5
WIO Slot2
PCIe adapter 6
WIO Slot3
PCIe adapter 7
Identifying the location of the GPU by using the slot number
The error message provides information to help you to determine the location of the graphics processing
unit (GPU).
For example, the log might contain an error similar to the following text:
[ 9288.123418] EEH: PHB#0 failure detected, location: WIO Slot1
Use the following table to map the slot number information in the operating system log to the GPU
description and service action.
Table 11. Slot numbers, GPU descriptions, and service action for the 8001-12C and 8005-12N
Slot information from the log
GPU description
Service action
WIO Slot1
GPU
Replace the GPU indicated in the
GPU description column. Go to
“8001-12C or 8005-12N locations” on
page 73 to identify the physical
location and the removal and
replacement procedure.
Table 12. Slot numbers, GPU descriptions, and service action for the 8001-22C and 8005-22N
Slot information from the log
GPU description
Service action
UIO Slot1
GPU 1
Replace the GPU indicated in the
GPU description column. Go to
“8001-22C or 8005-22N locations” on
page 87 to identify the physical
location and the removal and
replacement procedure.
WIO Slot1
GPU 2
Beginning troubleshooting and problem analysis
19