Hardware Maintenance Manual: Netfinity 4500R Type 8656
PCNTNW-NW-054 The adapter did not respond to the initialization command.
Explanation:
The adapter did not respond when the driver tried to initialize
it.
Action:
Verify that the Ethernet controller is enabled. If
the Ethernet controller is enabled, go to “Starting the diagnostic programs”
on page 14 to run the diagnostic programs.
PCNTNW-NW-058 The adapter did not respond to the initialization command.
Explanation:
The interrupt request (IRQ) setting might not be valid or the
EEPROM information might be incorrect.
Action:
Make
sure the IRQ settings are correct in the Configuration/Setup Utility
program. for information on setting the interrupt requests. If the IRQ
settings are correct, go to “Starting the diagnostic programs” on page 14 to
run the diagnostic programs.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
Explanation:
The cable might be disconnected from the server Ethernet port.
Action:
Verify that a cable is connected to the Ethernet port.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation:
You tried to load another instance of the driver with a different
I/O address. This new adapter could not be found.
Action:
Verify that you installed an IBM Netfinity 10/100 Fault Tolerant
Adapter and make sure that the adapter is seated correctly. If the adapter is
seated correctly, go to “Starting the diagnostic programs” on page 14 to run
the diagnostic programs..
PCNTNW-NW-072 A resource tag is unavailable
.
Explanation:
The driver tried to allocate some resources that were not
available.
Action:
Add more memory, or free some memory
resources in the server. Then, restart the server.
PCNTNW-NW-073 Unable to allocate memory
Explanation:
The driver failed to allocate the memory needed for normal
operation.
Action:
Add more memory, or free some memory
resources in the server. Then, restart the server.
PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation:
An attempt was made to initialize a given hardware interrupt.
The attempt was not successful.
Action:
Verify that the
Ethernet controller is enabled. If the Ethernet controller is enabled, go to
“Starting the diagnostic programs” on page 14 to run the diagnostic
programs.
If you have an Ethernet adapter installed, make sure that the adapter does
not share an IRQ with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the
Link Support Layer (LSL).
Explanation:
An error occurred while the driver was trying to register with
the LSL.
Action:
Check the version of the NetWare or
IntraNetWare Operating System. Make sure that this driver is correct for the
version of NetWare or IntraNetWare that you are using. Restart the server.
Table 2. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet controller.
Summary of Contents for Netfinity 4500R
Page 1: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 118: ...110 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 147: ...Parts listing Type 8656 139...
Page 148: ...140 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 161: ...Related service information 153...
Page 162: ...154 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 163: ...Related service information 155...
Page 164: ...156 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 165: ...Related service information 157...
Page 166: ...158 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 167: ...Related service information 159...
Page 168: ...160 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 181: ...Related service information 173...
Page 182: ...174 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 183: ...Related service information 175...
Page 191: ......