Symptom-to-FRU index
133
Bus fault messages
Undetermined problems
You are here because the diagnostic tests did not identify the failure, the Devices List
is incorrect, or the system is inoperative.
Note:
A corrupt CMOS can cause undetermined problems.
Check the LEDs on all the power supplies, see“Power supply LED errors” on page
121. If the LEDs indicate the power supplies are working correctly, return here and do
the following:
1.
Power-off the computer.
2.
Be sure the system is cabled correctly.
3.
Remove or disconnect the following (one at a time) until you find the failure
(power-on the computer and reconfigure each time).
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory-Modules (Minimum requirement = 128 MB (4x128 MB DIMMs))
Note:
Minimum operating requirements are:
a.
1 Power Supply
b. Power Backplane
c.
System Board
d. 1 Microprocessor and VRM
e.
1 Terminator Card
f.
Memory Module (with a minimum of 1 bank of 128 MB DIMMs)
4.
Power-on the computer. If the problem remains, suspect the following FRUs in
the order listed:
Power Supply
Power Backplane
Message
Action
Failure reading 12C device.
Check devices on bus 0.
1.
Replace system board
Failure reading 12C device.
Check devices on bus 1.
1.
Reseat power Supply
2.
Replace power supply
3.
Replace power supply backplane
4.
Replace system board
Failure reading 12C device.
Check devices on bus 2.
1.
Replace DASD backplane
2.
Replace system board
Failure reading 12C device.
Check devices on bus 3.
1.
Replace system board
Failure reading 12C device.
Check devices on bus 4.
1.
Replace DIMM
2.
Replace system board
Summary of Contents for Netfinity 4500R
Page 1: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 118: ...110 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 147: ...Parts listing Type 8656 139...
Page 148: ...140 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 161: ...Related service information 153...
Page 162: ...154 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 163: ...Related service information 155...
Page 164: ...156 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 165: ...Related service information 157...
Page 166: ...158 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 167: ...Related service information 159...
Page 168: ...160 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 181: ...Related service information 173...
Page 182: ...174 Hardware Maintenance Manual Netfinity 4500R Type 8656...
Page 183: ...Related service information 175...
Page 191: ......