286
IBM System Storage N series Hardware Guide
Table 20-4 shows the maximum number of dense volumes, snapshot copies, LUNs, and
vFiler units that are supported for NDU.
Table 20-4 Maximum limits for NDU
20.1.5 Prerequisites for a system NDU
The following sections describe the tasks that must be completed before a major or minor
system NDU is performed.
Reading the latest documentation
Review the Data ONTAP Upgrade Guide for the version to which you are upgrading, not the
version from which you are upgrading. These documents are available on the IBM NAS
Support site, which is available at:
http://www.ibm.com/storage/support/nas/
Verify that the system and hosts (if applicable) fulfill the requirements for upgrade.
Review the release notes for the version of Data ONTAP to which you are upgrading. Release
notes are available on the IBM Support site.
Review the list of any known installation or upgrade problems for both the version of Data
ONTAP to which you are upgrading, and all host-specific items if your environment uses FCP
or iSCSI.
Validating the storage controller system configurations
Confirm that both storage controllers are prepared for the NDU operation. Validate each
individual controller’s configuration to identify any issues before upgrading.
Create a detailed upgrade test procedure document and a back-out plan.
Identify any inconsistencies between the two storage controllers within the HA pair controller
configuration so that all identified issues can be corrected before beginning the upgrade.
Removing all failed disks
Failed disk drives prevent giveback operations and can introduce stack and loop instability
throughout the storage system. Remove or replace all failed disk drives before beginning the
system NDU operation.
Data ONTAP
Dense
volumes
Snapshot copies
LUNs
vFiler units
FC, SAS
storage
SATA
storage
FC, SAS
storage
SATA
storage
7.3.x to 8.0
100
500
500
2,000
64
5
7.3.x to 8.0.1
300
12,000
4,000
2,000
64
5
7.3.x to 8.1
300
12,000
4,000
2,000
64
5
8.0 to 8.0.x
300
12,000
4,000
2,000
64
5
8.0.x to 8.1
500
20,000
20,000
2,000
64
5
8.1 to 8.1.x
500
20,000
20,000
2,000
64
5
Summary of Contents for N Series
Page 2: ......
Page 12: ...x IBM System Storage N series Hardware Guide ...
Page 18: ...xvi IBM System Storage N series Hardware Guide ...
Page 20: ...xviii IBM System Storage N series Hardware Guide ...
Page 22: ...2 IBM System Storage N series Hardware Guide ...
Page 32: ...12 IBM System Storage N series Hardware Guide ...
Page 52: ...32 IBM System Storage N series Hardware Guide ...
Page 64: ...44 IBM System Storage N series Hardware Guide ...
Page 90: ...70 IBM System Storage N series Hardware Guide ...
Page 122: ...102 IBM System Storage N series Hardware Guide ...
Page 194: ...174 IBM System Storage N series Hardware Guide ...
Page 200: ...180 IBM System Storage N series Hardware Guide ...
Page 224: ...204 IBM System Storage N series Hardware Guide ...
Page 244: ...224 IBM System Storage N series Hardware Guide ...
Page 292: ...272 IBM System Storage N series Hardware Guide ...
Page 298: ...278 IBM System Storage N series Hardware Guide ...
Page 300: ...280 IBM System Storage N series Hardware Guide ...
Page 314: ...294 IBM System Storage N series Hardware Guide ...
Page 326: ...306 IBM System Storage N series Hardware Guide ...
Page 327: ... Copyright IBM Corp 2012 2014 All rights reserved 307 Part 5 Appendixes Part 5 ...
Page 328: ...308 IBM System Storage N series Hardware Guide ...
Page 362: ...342 IBM System Storage N series Hardware Guide ...
Page 366: ...IBM System Storage N series Hardware Guide IBM System Storage N series Hardware Guide ...
Page 367: ......