Chapter 9. MetroCluster expansion cabling
141
If there is similar output, disk drives with downrev firmware were detected and the
firmware is updated automatically. Go to the next step.
If there is no similar output, wait for an hourly message on the console and take the
applicable following action:
If there is no message on the console about disk drive firmware, this means that the disk
drive firmware is current and no action is needed.
If there is a message containing
disk.fw.downrevWarning
and text stating disks have
downrev firmware that you must update, update the disk drive firmware by completing the
following steps:
Actual output might look similar to the following example:
Sun May 5 04:00:01 PDT [svt-6040-01: disk.fw.downrevWarning:warning]: 1 disks
have downrev firmware that you need to update.
a. Download the disk drive firmware from the IBM N series support site.
b. Enter the following command at the storage system console to update the disk drive
firmware:
disk_fw_update
You must run this command on both controllers.
2. Complete the following steps to verify that the disk shelf firmware is the most current
version:
a. Enter the following command at the storage system console:
sasadmin expander_map
b. Locate the disk shelf firmware information for the hot-added disk shelf in the output.
Example: 0151 is the disk shelf firmware version for shelf number one (Slot A/IOM A) in
the storage system, as shown in the following example:
Expanders on channel 4a:
Level 3: WWN 500a0980000840ff, ID 1, Serial Number ' SHU0954292G114C',
Product 'DS424IOM6', Rev '0151', Slot A
c. Compare the firmware information in the command output with the disk shelf firmware
information at the IBM N series support site to determine the most current disk shelf
firmware version.
3. The next step depends on how current the disk shelf firmware is:
– If the firmware version in the command output is the same as or later than the most
current version on the N series support site, no disk shelf firmware update is needed.
– If the firmware version in the command output is an earlier version than the most
current version on the N series support site, download and install the new disk shelf
firmware file. You can run the commands from either node.
9.2.5 Replacing FibreBridge and SAS copper cables with SAS optical cables
You must halt both controllers of the stretch MetroCluster to replace all FibreBridge 6500N
bridges, shelf-to-shelf SAS copper cables, and bridge-to-shelf SAS copper cables with SAS
optical cables.
Attention: Running this command delays I/O on the disk drives on which you are
updating the firmware.
Summary of Contents for N Series
Page 2: ......
Page 12: ...x IBM System Storage N series Hardware Guide ...
Page 18: ...xvi IBM System Storage N series Hardware Guide ...
Page 20: ...xviii IBM System Storage N series Hardware Guide ...
Page 22: ...2 IBM System Storage N series Hardware Guide ...
Page 32: ...12 IBM System Storage N series Hardware Guide ...
Page 52: ...32 IBM System Storage N series Hardware Guide ...
Page 64: ...44 IBM System Storage N series Hardware Guide ...
Page 90: ...70 IBM System Storage N series Hardware Guide ...
Page 122: ...102 IBM System Storage N series Hardware Guide ...
Page 194: ...174 IBM System Storage N series Hardware Guide ...
Page 200: ...180 IBM System Storage N series Hardware Guide ...
Page 224: ...204 IBM System Storage N series Hardware Guide ...
Page 244: ...224 IBM System Storage N series Hardware Guide ...
Page 292: ...272 IBM System Storage N series Hardware Guide ...
Page 298: ...278 IBM System Storage N series Hardware Guide ...
Page 300: ...280 IBM System Storage N series Hardware Guide ...
Page 314: ...294 IBM System Storage N series Hardware Guide ...
Page 326: ...306 IBM System Storage N series Hardware Guide ...
Page 327: ... Copyright IBM Corp 2012 2014 All rights reserved 307 Part 5 Appendixes Part 5 ...
Page 328: ...308 IBM System Storage N series Hardware Guide ...
Page 362: ...342 IBM System Storage N series Hardware Guide ...
Page 366: ...IBM System Storage N series Hardware Guide IBM System Storage N series Hardware Guide ...
Page 367: ......