Error code
Qualifiers
Hex error
Description
Recovery procedure
0
00H
Qualifier code is unknown.
Check the error code.
0
0AH
Plunge motion system detected
an over voltage.
Check the error code. Clear the transport path.
11
0BH
Plunge motion system detected
an over force.
Turn off the unit. Clear the transport path. Turn on
the unit.
12
0CH
Plunge motion system detected
an error.
Turn the unit off and then on. Clear the transport
path.
13
0DH
Plunge motion system timed
out.
Turn the unit off and then on.
19
13H
Translate motion system
detected an unknown error.
Check the error code. Clear the transport path.
20
14H
Translate motion system
detected an over voltage.
Clear the transport path.
21
15H
Translate motion system
detected an over force.
Turn off the unit. Clear the transport path.
22
16H
Translate motion system
detected an error.
Turn the unit off and then on. Clear the transport
path.
26
1AH
Translate motion system failed
to detect a hardstop or the
edge of the frame.
Run Recalibrate Loader test. Run Test Lateral
Encoder test.
29
1DH
The translate motion system
attempted a move when it was
not ready.
Run Recalibrate Loader from panel test.
33
21H
Failed to detect a cartridge in
the drive.
Run Recalibrate Loader test, followed by Check
Inventory test. Turn the unit off and then on.
36
24H
Drive module failed to eject a
tape.
Take the drive off- and online. Turn the unit off and
then on.
37
25H
Failed to detect the drive
hardstop while loading a tape.
Run Recalibrate Loader test, followed by Check
Inventory test. Turn the unit off and then on.
42
2AH
Drive module is missing or not
communicating.
Check that the drive is installed and online.
47
2FH
Drive module fan is not
working properly.
Check for obstructions in the drive fan. Try bringing
the drive back online. Replace the drive.
48
30H
Failed to detect that the
transport has loaded a tape.
Run Test Lateral Loader test, Recalibrate Loader test,
followed by Check Inventory.
50
32H
Failed to detect the magazine
hardstop while loading a tape.
Run Test Lateral Loader test, Recalibrate Loader test,
followed by Check Inventory.
54
36H
Failed to detect the magazine
hardstop while removing a
tape.
Run Recalibrate Loader test, followed by Check
Inventory test. Turn the unit off and then on.
56
38H
Failed to empty the transport
during an inventory check.
Ensure there is a vacant slot. Run Recalibrate
Loader test, followed by Check Inventory test.
60
3CH
Internal communication on I2C
bus has failed.
Run Recalibrate Loader test, followed by Check
Inventory test. Turn the unit off and then on.
83
53H
Failed during a diagnostic test. Run Recalibrate Loader test, followed by Check
Inventory test. Run diagnostic again.
86
56H
Timed out on a command sent
to the transport controller.
Verify that the transport LEDs are on and green.
Clear any obstructions from the transport path.
87
57H
A command to the transport
controller was corrupted.
Turn the unit off and then on.
88
58H
Attempted to overlap
commands to the transport
controller.
Run Recalibrate Loader test. Clear the transport
path. Turn the unit off and then on.
36
LTO Autoloader: User’s Guide
Summary of Contents for LTO
Page 1: ...LTO Autoloader User s Guide IBM...
Page 2: ......
Page 3: ...LTO Autoloader User s Guide IBM...
Page 6: ...iv LTO Autoloader User s Guide...
Page 8: ...vi LTO Autoloader User s Guide...
Page 11: ...6 Power cord receptacle 7 SCSI connectors Chapter 1 Installation and user s guide 3...
Page 20: ...12 LTO Autoloader User s Guide...
Page 32: ...24 LTO Autoloader User s Guide...
Page 38: ...30 LTO Autoloader User s Guide...
Page 50: ...42 LTO Autoloader User s Guide...
Page 68: ...60 LTO Autoloader User s Guide...
Page 69: ......