Not
Applicable
You
attempted
to
test
a
device
that
is
not
present
in
the
computer.
Aborted
The
test
could
not
proceed
because
of
the
computer
configuration.
Warning
The
test
could
not
be
run.
There
was
no
failure
of
the
hardware
that
was
being
tested,
but
there
might
be
a
hardware
failure
elsewhere,
or
another
problem
prevented
the
test
from
running;
for
example,
there
might
be
a
configuration
problem,
or
the
hardware
might
be
missing
or
it
is
not
detected.
test_specific_string
is
an
error
code
or
other
information
about
the
error.
Diagnostic
error
codes
The
following
table
describes
the
error
codes
that
the
diagnostic
programs
might
generate
and
suggested
actions
to
correct
the
detected
problems.
If
the
diagnostic
programs
generate
error
codes
that
are
not
listed
in
the
table,
make
sure
that
the
latest
levels
of
BIOS
code
and
firmware
are
installed.
In
the
error
codes,
x
can
be
any
numeral
or
letter.
However,
if
the
three-digit
number
in
the
central
position
of
the
code
is
000,
195,
or
197,
do
not
replace
a
CRU
or
FRU.
These
numbers
appearing
in
the
central
position
of
the
error
code
have
the
following
meaning:
000
The
computer
passed
the
test.
Do
not
replace
a
CRU
or
FRU.
195
The
Esc
key
was
pressed
to
end
the
test.
Do
not
replace
a
CRU
or
FRU.
197
This
is
a
warning
error,
but
it
does
not
indicate
a
hardware
failure;
do
not
replace
a
CRU
or
FRU.
Take
the
action
that
is
indicated
in
the
Action
column,
but
do
not
replace
a
CRU
or
FRU.
See
the
description
of
Warning
in
for
more
information.
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
(Trained
service
technician
only),
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
001-197-000
001-198-000
Test
aborted.
1.
Check
the
test
log
for
messages
indicating
the
cause
of
the
error,
and
take
the
indicated
action.
2.
From
the
diagnostic
programs,
run
Quick
Memory
Test
All
Banks;
then,
if
an
error
is
detected,
take
the
indicated
action.
3.
Reinstall
and,
if
necessary,
update
the
BIOS
code
on
the
server;
then,
rerun
the
test
(see
42
IBM
IntelliStation
A
Pro
Type
6217:
Problem
Determination
and
Service
Guide
Summary of Contents for IntelliStation A Pro 6217
Page 1: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 94: ...78 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 158: ...142 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 170: ...154 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 186: ...170 IBM IntelliStation A Pro Type 6217 Problem Determination and Service Guide...
Page 187: ......
Page 188: ...Part Number 31R1994 Printed in USA 1P P N 31R1994...