Diagnostics
7
4.
Using the cursor movement keys, highlight a single test within a test category,
then press Enter. This will run only that test.
Press Esc at any time to stop the testing process.
Test results, (N/A, PASSED, FAILED, ABORTED), are displayed in the field beside
the test description and in the test log. See “Viewing the test log” on page 10.
Test selection
To select one or more tests, use the following procedure.
1.
Open the corresponding test category.
2.
Using the cursor movement keys, highlight the desired test.
3.
Press the space bar.
A selected test is marked by >>. Pressing the space bar again de-selects a test and
removes the chevron.
4.
Repeat steps 2 and 3 above to select all desired tests.
Module test menu/hardware configuration report
Depending on the diagnostics version level you are using, the installed devices in the
computer are verified in one of two ways.
1.
At the start of the diagnostic tests, the Module Test Menu is displayed. Normally,
all installed devices in the computer are highlighted on the menu.
2.
At the start of the diagnostic tests, the main menu appears. From this menu, select
System Info
, then select Hardware Configuration from the next menu. Normally,
all installed devices in the computer are highlighted on this report.
If an installed device is not recognized by the diagnostics program, then review the
following:
•
The diagnostic code for the device is not in the Diagnostics program. Run the
diagnostics provided with that device.
•
The missing device is defective or it requires an additional diskette or service
manual.
•
An unrecognizable device is installed.
•
A defective device is causing another device not to be recognized.
•
The SCSI controller failed (on the system board or SCSI adapter).
•
Use the procedure in “Undetermined problems” on page 81 to find the problem.
If a device is missing from the list, replace it. If this does not correct the problem, use
the procedure in “Undetermined problems” on page 81.
Memory Diagnostic tests
The Memory Diagnostics provide the capability to identify a particular memory
module (SIMM, DIMM, or RIMM) which fails during testing. Use the System Board
Layout section to reference the memory sockets, or select F1twice to load the
Diagnostics online manual and select "SIMM/DIMM/RIMM Locator".
Follow the steps below to locate the Memory Diagnostic tests options.
1.
Select the DIAGNOSTICS option on the toolbar and press Enter.
Summary of Contents for IntelliStation 6866
Page 1: ...IBM IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 2: ......
Page 3: ...IBM IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 20: ...12 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 52: ...44 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 90: ...82 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 98: ...90 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 106: ...98 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 113: ...Related service information 105 ...
Page 114: ...106 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 115: ...Related service information 107 ...
Page 116: ...108 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 117: ...Related service information 109 ...
Page 123: ...Related service information 115 ...
Page 128: ...120 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 129: ...Related service information 121 ...
Page 130: ...122 IBM IntelliStation Type 6866 Hardware Maintenance Manual ...
Page 147: ......