On
the
Choose mksysb Device
menu, type the number of the device with the
backup tape mounted and press enter. The restore will now begin. A progress
screen will be displayed until the restore is complete.
Once the restore is complete, the VIOS will reboot from the just completed restore image.
After restoring VIOS, restore the partition data. The partition data can be restored by using the
following command on the VIOS console (assuming you used the
bkprofdata
command as
described above):
rstprofdata –l 1 –f profile.bak --ignoremtms
.
The partition data can also be restored through IVM using the following steps:
•
Log into the Integrated Virtualization Manager using the
padmin
profile
•
On
the
Service Management
menu, click
Backup/Restore
.
•
On
the
Partition Configuration Backup/Restore
tab, the Partition Configuration
Backup file should be listed. Click the
Restore Partition Configuration
button to
restore the listed configuration.
8. i Edition Express for BladeCenter S
8.1. Overview
The i Edition Express for BladeCenter S is a packaged solution that includes a BladeCenter S
chassis with SAS disk drives, a JS12 Power blade server, IBM PowerVM and IBM i for 10 users.
It is an integrated offering priced similarly to a Power 520 Express i Edition that makes it easier
for clients to consolidate their existing IBM i and Windows workloads in a BladeCenter
environment. For the minimum i Edition Express for BladeCenter S hardware configuration and
further details, consult http://www.ibm.com/systems/power/hardware/blades/iedition.html. Note
that service vouchers are not available for the JS12 when it is part of an i Edition Express order.
Service vouchers are otherwise available for IBM i on all Power blades. See the following
Website for details and voucher registration:
http://www.ibm.com/systems/power/hardware/vouchers/index.html.
Every i Edition Express for BladeCenter S will automatically get VIOS and IBM i preloaded on the
JS12. See the next section in this document for an overview of the IBM i preinstall on
BladeCenter S and the post-ship configuration actions that must be performed by the
implementing party.