Symptom
Action
The
blade
workstation
does
not
turn
on.
1.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75).
2.
Make
sure
that
the
power-on
LED
on
the
blade
workstation
control
panel
is
flashing
slowly.
v
If
the
power
LED
is
flashing
rapidly
and
continues
to
do
so,
the
blade
workstation
is
not
communicating
with
the
management-module;
reseat
the
blade
workstation
and
go
to
step
7.
v
If
the
power
LED
is
off,
the
blade
bay
is
not
receiving
power,
the
blade
workstation
is
defective,
or
the
LED
information
panel
is
loose
or
defective.
3.
Check
the
power-management
policies
in
the
operating
system
for
the
blade
workstation.
4.
Check
the
management
module
log
of
the
corresponding
blade
workstation
for
an
error
preventing
the
blade
workstation
from
turning
on.
5.
Reseat
the
blade
workstation.
6.
If
you
just
installed
a
device
in
the
blade
workstation,
remove
it
and
restart
the
blade
workstation.
If
the
blade
workstation
now
starts,
you
might
have
installed
more
devices
than
the
power
to
that
blade
bay
supports.
7.
(Trained
service
technician
only)
If
you
tried
another
blade
workstation
in
the
blade
bay
when
checking
the
function
of
the
shared
BladeCenter
unit
resources
and
the
other
blade
workstation
worked,
replace
the
system
board
assembly.
8.
See
“Solving
undetermined
problems”
on
page
80.
The
blade
workstation
turns
off
for
no
apparent
reason.
1.
Check
the
function
of
the
shared
BladeCenter
unit
resources
(see
“Solving
shared
BladeCenter
resource
problems”
on
page
75).
2.
(Trained
service
technician
only)
If
the
microprocessor
error
LED
is
lit,
replace
the
microprocessor.
3.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
The
blade
workstation
does
not
turn
off.
1.
Verify
whether
you
are
using
an
Advanced
Configuration
and
Power
Interface
(ACPI)
or
non-ACPI
operating
system.
2.
If
you
are
using
a
non-ACPI
operating
system,
complete
the
following
steps:
a.
Turn
off
the
blade
workstation
by
pressing
the
power-control
button
for
4
seconds.
b.
If
the
blade
workstation
fails
during
POST
and
the
power-control
button
does
not
work,
remove
the
blade
workstation
from
the
bay
and
reseat
it.
3.
If
the
problem
remains
or
if
you
are
using
an
ACPI-aware
operating
system,
complete
the
following
steps:
a.
Check
the
power-management
policies
in
the
operating
system
for
the
blade
workstation.
b.
(Trained
service
technician
only)
Replace
the
system
board
assembly.
Chapter
5.
Diagnostics
65
Summary of Contents for HC10 - BladeCenter - 7996
Page 1: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 8: ...vi BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 16: ...xiv BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 54: ...38 BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 112: ...96 BladeCenter HC10 Type 7996 Problem Determination and Service Guide...
Page 113: ......
Page 114: ...Part Number 42C4881 Printed in USA 1P P N 42C4881...