Table 11. Temperature requirements
Environment
Ambient
temperature
Altitude
Relative humidity
Maximum dew
point
Operating
10° C to 35° C (50°
F to 95° F)
0 - 3050 m (0 -
10,006 ft)
20% to 80% non-condensing
21°C (69° F)
Non-operating
-10° C to 50° C (14°
F to 125° F)
0 - 3050 m (0 -
10,006 ft)
8% to 80% non-condensing
27°C (80° F)
Storage
1° C to 60° C (33° F
to 140° F)
No limit
5% to 80% non-condensing
29°C (84° F)
Shipping
-40° C to 60° C
(-40° F to 140° F)
No limit
5% to 100% non-condensing
29°C (84° F)
Physical characteristics
Table 12 on page 8 summarizes the dimension and weight information for the FlashSystem 5000
control and expansion enclosures. Ensure that the rack has enough available space to support each type
of enclosure.
Table 12. Enclosure physical characteristics
Enclosure type Model
Height
Width
Depth
Maximum weight
Drive ready
(without
drives)
Fully
configured
(with drives)
Control
enclosures (12
LFF drive slots)
FlashSystem
5010
( 2072-2H2 )
FlashSystem
5030
( 2072-3H2 )
FlashSystem
5010 (2072-
S12)
FlashSystem
5030 (2072-
T12)
8.7 cm (3.4 in)
48.3 cm (19.0
in)
55.6 cm (21.9
in)
18.0 kg (39.6
lb)
28.3 kg (62.2
lb)
Control
enclosures (24
SFF drive slots)
FlashSystem
5010
( 2072-2H4 )
FlashSystem
5030
( 2072-3H4 )
FlashSystem
5010 (2072-
S24)
FlashSystem
5030 (2072-
T24)
8.7 cm (3.4 in)
48.3 cm (19.0
in)
55.6 cm (21.9
in)
19.0 kg (41.8
lb)
27.3 kg (60.0
lb)
8 IBM FlashSystem 5000 : FlashSystem 5000 Quick Installation Guide
Summary of Contents for FlashSystem 5000 Series
Page 6: ...vi IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 18: ...xviii IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 38: ...20 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 94: ...76 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 96: ...78 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 98: ...80 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 105: ......
Page 106: ...IBM...