Figure 63. Connecting the Ethernet cables to a FlashSystem 5010 system
c) Optional: Connect Ethernet port 2 of each node canister in the system to a second IP network, as
shown by the blue cable connection in Figure 63 on page 65. This second port can be used to
provide a redundant connection to the system management interfaces; it can also be used for iSCSI
connectivity to the system by hosts on the network.
Note: On FlashSystem 5010 systems, the second Ethernet port is also used as the technician port.
Do not connect Ethernet port 2 to the SAN until the management GUI setup wizard completes on
each system and the cluster is created. If you have to service your system, disconnect port 2 from
the SAN before you enable port 2 to be the technician port again.
2. If you have a FlashSystem 5030 system, complete the following steps.
a) Identify the location and function of the Ethernet ports on your system; refer to Figure 64 on page
65.
• The technician port should only be used to initialize or service the system. In Figure 64 on page
65, the technician port is identified by the green cable (
T
).
Note: Never use the technician port to provide an Ethernet connection to the system. Do not
connect the Ethernet technician port to a network switch. The technician port must only be
directly connected to a personal computer when initializing a system or servicing a node.
• Ethernet port 1 can be used to provide Ethernet connections. In the figure, port 1 is identified by
the blue cable (
1
).
• Ethernet port 2 can optionally be used to provide additional Ethernet connections. In the figure,
port 2 is identified by the red cable (
2
). Port 2 can also be used for iSCSI connectivity or IP
replication.
b) Connect Ethernet port 1 of each FlashSystem 5030 node canister in the system to the IP network
that will provide a connection to the system management interfaces. Figure 64 on page 65 shows
the port locations and Ethernet cabling on a FlashSystem 5030 node canister.
Figure 64. Connecting the Ethernet cables to a FlashSystem 5030 system
c) Optional: Connect Ethernet port 2 of each node canister in the system to a second IP network, as
shown by the red cable connection in Figure 64 on page 65. Port 2 can provide a redundant
Chapter 4. Installing the system hardware 65
Summary of Contents for FlashSystem 5000 Series
Page 6: ...vi IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 18: ...xviii IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 38: ...20 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 94: ...76 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 96: ...78 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 98: ...80 IBM FlashSystem 5000 FlashSystem 5000 Quick Installation Guide...
Page 105: ......
Page 106: ...IBM...