Ethernet controller messages
The integrated Ethernet controllers might display messages from device drivers for
TurboLinux 6.05.
This section provides explanations of the error messages for the TurboLinux Ethernet
controller device driver, and suggested actions to resolve each problem.
Table 17. TurboLinux driver messages for the Ethernet controller
Error code (hex)
Description
0x00
Explanation:
The device driver could not register the specified interrupt.
Action:
Using the Configuration/Setup Utility program, make sure that a PCI interrupt is assigned
to your Ethernet adapter, and that Ethernet is enabled.
0x01
Explanation:
One of the PCI cards did not get the required resources.
Action:
Using the Configuration/Setup Utility program, make sure that a PCI interrupt is assigned
to your Ethernet card, and that Ethernet is enabled. See “Using the Configuration/Setup Utility
program” on page 12.
0x02
Explanation:
Bad node address (multicast address).
Action:
Make sure the locally administered address is valid, if one is specified. The address cannot
be a multicast address.
0x03
Explanation:
Failed self-test.
Action:
Make sure a cable is attached to the Ethernet connector. If the problem persists, call for
service.
0x0D
Explanation:
Could not allocate enough memory for transmit queues.
Action:
1. From the Windows NT desktop, click Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Click Properties -> Advanced.
4. Lower the resource values that apply to the transmit queue.
0x0E
Explanation:
Could not allocate enough memory for receive queue.
Action:
1. From the Windows NT desktop, click Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the resource values that apply to the receive queue.
0x0F
Explanation:
Could not allocate enough memory for other structures.
Action:
1. From the Windows NT desktop, select Start -> Control Panel -> Networks -> Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Select Properties -> Advanced.
4. Lower the value for the resource named in the message.
0x10
Explanation:
Did not find any Ethernet controllers.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled. See
“Using the Configuration/Setup Utility program” on page 12.
0x11
Explanation:
Multiple Ethernet controllers found, but none matched the required ID.
Action:
Using the Configuration/Setup Utility program, make sure that Ethernet is enabled. See
“Using the Configuration/Setup Utility program” on page 12.